Science Park Sewer Systems Effluent Standards
颁布于 2012-12-10 · 文本截至 2026-10-01
以研究形式发布的公开法律与官方指引,不构成法律、税务或金融建议。
研究内容本身以英文撰写。标题和标签已翻译,调查结果和引文未翻译。
关于这部法律
- 原标题
- 科學工業園區污水下水道系統放流水標準.
- 语言
- English
- 类型
- 其他
- 国家
- 台湾
- 主题
- Environment, Water
- 关键词
- pollution control, effluent waste water/discharge, sewerage, standards, freshwater pollution
在哪里阅读
该法律没有记录来源链接。
文本
所收录的法律原文,按条款排列。每个条款都有自己的链接。
Science Park Sewer Systems Effluent Standards Nine articles promulgated by Environmental Protection Administration Order Huan-Shu-Shui-Tzu No. 1010090484 on October 12, 2012. Article 1 These Standards are determined pursuant to Article 7, Paragraph 2 of the Water Pollution Control Act. Article 2 Terms used in these Standards are defined as follows: I. "Seven-day average values" means the values are derived by mixing four daily water samples, taken at intervals of from four to eight hours, to perform one water sample test; the average is then taken of test values for seven consecutive days II. "TTO" means the concentrations of any of the following 30 types of chemical compounds: 1,2-Dichlorobenzene, 1,3-Dichlorobenzene, 1,4-Dichlorobenzene, 1,2,4-Trichlorobenzene, Toluene, Ethylbenzene, Chloroform, 1,2-Dichloroethane, Dichloromethane, 1,1,1-Trichloroethane, 1,1,2-Trichloroethane, Dichlorobromomethane, Tetrachloroethylene, Trichloroethene, 1,1-Dichloroethene, 2-Chlorophenol, 2,4-Dichlorophenol, 4-Nitrophenol, Pentacholorophenol, 2-Nitrophenol, Phenols, 2,4,6-Trichlorophenol, Bis(2-ethylhexyl) phthalate (DEHP), Dibutyl phthalate (DBP), Benzyl butyl phthalate (BBP), Anthracene, 1,2-Diphenylhydrazine, Isophorone, and Carbon Tetrachloride. III. "Newly-established sewer system" means Science Park Sewer Systems for which planning had not been completed as of October 12, 2012, or for which planning had been completed, but project bid request procedures had not yet been completed as of that time. IV. "Existing sewer system " means Science Park Sewer Systems that had been completed, were in construction, or for which project bid request procedures had been completed as of October 12, 2012. Article 3 These Standards are applicable to Science Park Sewer Systems. Article 4 See the Attached Table for the water quality items and limits prescribed in these Standards. Article 5 Science Park Sewer Systems or relevant environmental groups may submit detailed scientific data and information to the Responsible Agency at the central government level to support argument for revision of these Standards. Article 6 The COD limits determined in these Standards shall be tested using the potassium dichromate oxidation method; the true color shall be tested using true color colorimetry. Article 7 Concerning the limits in the foregoing paragraph, apart from the pH, which is defined as a range and not in units, the rest are defined as the maximum allowed value using the following units of measure: I. Water temperature: Celsius (℃)。 II. True color: Unitless III. Other items: Milligrams per liter (mg/L)。 Article 8 With regard to the limits for the items in these Standards, apart from water temperature and pH, these standards shall not apply when Science Park Sewer System obtains water from a water body for non-contact cooling or circulating cooling and such water is discharged to the surface water body from which it was originally obtained. Article 9 Unless an enforcement date is separately designated, these standards shall take effect on the date of promulgation. Attached Table Item Limit Remarks Water temperature 38 ℃ (applicable to the period from May to September) Applicable to the discharging of effluents into surface water bodies other than the ocean. 35 ℃ (applicable to the period from October to April of the following year) 42 ℃ , and the temperature difference may not exceed 4 ℃ for surface water at 500 meters from the discharge point. Applicable to effluents directly discharged into the sea. pH 6.0 - 9.0 Fluorides 15 Nitrate nitrogen 50 Ammonia nitrogen 10 Applicable to sewer system discharging wastewater or sewage into water source water quality protection zones. 20 Applicable to newly-established sewer system not discharging wastewater or sewage into water source water quality protection zones. 75 1.Applicable to existing sewer system not discharging wastewater or sewage into a water source water quality protection zones; enforced from July 1, 2013. 2. When a project or other improvement measure is involved, the Science Park sewer system shall submit an effluent pollutant reduction management plan by March 31, 2013, and shall implement the content of said plan after approval by the special municipality, county, or city competent authority; enforced from January 1, 2015. 30 Applicable to existing sewer system not discharging wastewater or sewage into a water source water quality protection zones; enforced from January 1, 2017. Orthophosphates (calculated as trivalent phosphate radicals) 4.0 Applicable to enterprises discharging wastewater or sewage into water source water quality protection zones. Phenols 1.0 Anionic surfactants 10 Cyanide 1.0 Oil and grease (n-hexane extract) 10 Soluble iron 10 Soluble manganese 10 Cadmium 0.03 Lead 1.0 Total chromium 2.0 Hexavalent chromium 0.5 Methylmercury not detectable Total mercury 0.005 Copper 3.0 Zinc 5.0 Silver 0.5 Nickel 1.0 Selenium 0.5 Arsenic 0.5 Boron 1.0 Sulfide 1.0 Biological oxygen demand (BOD) Maximum value 30 Seven-day average value 25 Chemical oxygen demand (COD) Maximum value 100 Seven-day average value 80 Suspended solids Maximum value 30 Seven-day average value 25 Biological oxygen demand (BOD) Maximum value 25 1. Effective from January 1, 2016. 2.Applicable to Science Park sewer systems for which planning had not been completed by July 31, 2009 or planning had been completed but project bid requests had not yet been made, and for which project bid requests had been made by July 31, 2009 with permit-approved effluent volume exceeding 10,000 CMD. Seven-day average value 20 Chemical oxygen demand (COD) Maximum value 80 Seven-day average value 65 Suspended solids Maximum value 25 Seven-day average value 20 True color 550 Indium 0.1 Applicable to Science Park sewer systems when the connected water volume approved on “wafer and semiconductor manufacturing industry” and “optoelectronic materials and component manufacturing industry” permits exceeds 50% of the permit-approved effluent volume. Gallium 0.1 Molybdenum 0.6 Total toxic organics(TTO) 1.37