跳到主要内容
Nelum
台湾的法律

Drinking Water Quality Standards

颁布于 1998-02-04 · 文本截至 2026-10-01

以研究形式发布的公开法律与官方指引,不构成法律、税务或金融建议。

研究内容本身以英文撰写。标题和标签已翻译,调查结果和引文未翻译。

关于这部法律

原标题
飲用水水質標準.
语言
English; Chinese
类型
其他
国家
台湾
主题
Water
关键词
potable water, water supply, equipment, water resources management, freshwater pollution, public water, water quality standards, pollution control

在哪里阅读

    该法律没有记录来源链接。

文本

所收录的法律原文,按条款排列。每个条款都有自己的链接。

  1. 6/13/2017 英譯法規內容 https://oaout.epa.gov.tw/law/PrintEngLawContent.aspx?Type=E&id=171 1/7 英譯法規內容 法規名稱 (Title): Drinking Water Quality Standards 公發布日 (Date): 2017.01.10 法規沿革: (Legislative) 1.Nine Articles drafted and promulgated by Environmental Protection Administration Order (87) Huan-Shu Tu-Tzu No. 004428 on February 4, 1998 2.Revisions to Article 3 promulgated by Environmental Protection Administration Order Huan-Shu-Tu Tzu No. 0920028896 on May 7, 2003 3.Revisions to Articles 3, 4, 5 and 6 promulgated by Environmental Protection Administration Order Huan Shu-Tu-Tzu No. 0940039894 on May 30, 2005 4.Revisions to Article 3 promulgated by Environmental Protection Administration Order Huan-Shu-Tu Tzu No. 0960100652 on January 2, 2008 5.Revisions to Article 3 promulgated by Environmental Protection Administration Order Huan-Shu-Tu Tzu No.0980106331E on November 26, 2009. 6.Revisions to Article 3 promulgated by Environmental Protection Administration Order Huan-Shu-Tu Tzu No.1030001229 on January 9, 2014. 7.Revisions to Article 3, 4, 5 promulgated by Environmental Protection Administration Order Huan-Shu-Tu Tzu No.1060000881 on January 10, 2017. 法規內文(Content): Article1 These Standards are determined pursuant to Article 11, Paragraph 2 of the Drinking Water Management Act (herein referred to as "this Act"). Article2 These standards shall apply to drinking water supplied from drinking water equipment designated in Article 4 of this Act and other drinking water designated by the central competent authority. Article3 Regulations of these standards are set forth herein. I. Bacterial standards: (Samples for total bacterial count must be collected from the finished water distribution networks that receive water from water treatment utilities with disinfection regime) Item Maximum limit Unit 1. Coliform group 6 (Multiple-tube fermentation method) Most probable number (MPN)/100 milliliters 6 (Membrane filtration method) Colony-forming unit(CFU)/100 milliliters 2. Total bacterial count 100 Colony-forming unit(CFU)/milliliter II. Physical standards: Item Maximum limit Unit 1. Odor 3 Threshold odor number (TON) 2. Turbidity 2 NTU (nephelometric turbidity unit) 3. Color 5 Platinum-cobalt unit III. Chemical standards: 6/13/2017 英譯法規內容 https://oaout.epa.gov.tw/law/PrintEngLawContent.aspx?Type=E&id=171 2/7 A. Substances that impact health: Item Maximum limit Unit 1. Arsenic 0.01 milligrams/liter 2. Lead 0.01 milligrams/liter 3. Selenium 0.01 milligrams/liter 4. Total chromium 0.05 milligrams/liter 5. Cadmium 0.005 milligrams/liter 6. Barium 2.0 milligrams/liter 7. Antimony 0.01 milligrams/liter 8. Nickel 0.1 0.07 This standard is effective starting on July 1, 2018. 0.02 This standard is effective starting on July 1, 2020. milligrams/liter 9. Mercury 0.002 0.001 This standard is effective starting on July 1, 2020. milligrams/liter 10. Cyanide (as CN-) 0.05 milligrams/liter 11. Nitrite-nitrogen 0.1 milligrams/liter Disinfection byproducts 12. Total Trihalomethanes 0.08 milligrams/liter 13. Haloacetic acids (This concentration is defined as the sum of measured concentrations for five haloacetic acids, including monochloroacetic acid (MCAA), dichloroacetic acid (DCAA), trichloroacetic acid (TCAA), monobromoacetic acid (MBAA), and dibromoacetic acid.) 0.060 milligrams/liter 14. Bromate 0.01 milligrams/liter 15. Chlorite 0.7 milligrams/liter 6/13/2017 英譯法規內容 https://oaout.epa.gov.tw/law/PrintEngLawContent.aspx?Type=E&id=171 3/7 (This regulation only applies to water supply systems that use gaseous chlorine dioxide as disinfectant) Volatile organic compounds 16. Trichloroethene 0.005 milligrams/liter 17. Carbon tetrachloride 0.005 milligrams/liter 18. 1,1,1-Trichloroethane 0.20 milligrams/liter 19. 1,2-Dichloroethane 0.005 milligrams/liter 20. Vinyl chloride 0.002 0.0003 This standard is effective starting on July 1, 2018. milligrams/liter 21. Benzene 0.005 milligrams/liter 22. 1,4-Dichlorobenzene 0.075 milligrams/liter 23. 1.1-Dichloroethylene 0.007 milligrams/liter 24. Dichloromethane 0.02 milligrams/liter 25. 1,2-Dichlorobenzene 0.6 milligrams/liter 26. Toluene 0.7 milligrams/liter 27. Xylenes (This regulated concentration for Xylenes is defined as the sum of the measured concentrations of three xylene isomers, including 1,2-Xylene, 1,3 Xylene, and 1,4-Xylene.) 0.5 milligrams/liter 28. Cis-1,2-Dichloroethene 0.07 milligrams/liter 29. Trans-1,2-Dichloroethene 0.1 milligrams/liter 30. Tetrachloroethene 0.005 milligrams/liter Agricultural chemicals 31. Endosulfan 0.003 milligrams/liter 32. Lindane 0.0002 milligrams/liter 33. Butachlor 0.02 milligrams/liter 34. Dichlorophenoxyacetic acid 0.07 milligrams/liter 35. Paraquat 0.01 milligrams/liter 36. Methomyl 0.01 milligrams/liter 37. Carbofuran 0.02 milligrams/liter 6/13/2017 英譯法規內容 https://oaout.epa.gov.tw/law/PrintEngLawContent.aspx?Type=E&id=171 4/7 38. Isoprocarb 0.02 milligrams/liter 39. Methamidophos 0.02 milligrams/liter 40. Diazinon 0.005 milligrams/liter 41. Parathion 0.02 milligrams/liter 42. EPN 0.005 milligrams/liter 43. Monocrotophos 0.003 milligrams/liter Persistent organic pollutants 44 Dioxin This regulated concentration for Dioxin is defined as the sum of the measured concentrations of 17 compounds, including 2,3,7,8-Tetrachlorinated dibenzo-p-dioxin-2,3,7,8 TeCDD, 2,3,7,8-Tetra chlorinated dibenzofuran,2,3,7,8-TeCDF and 2,3,7,8- penta-, hexa-, hepta-, and octa-chlorinated dioxins and furan. This regulated concentration for Dioxin is multiplied by the dioxin toxic equivalency factor (WHO-TEFs) provided by World Health Organization, and is expressed as a total toxicity equivalency quantity (TEQ). (If any drinking water treatment facilities locate within a 5-kilometer distance having a large pollution source, it must be monitored once every year. If the measured Dioxin concentrations do not exceed the maximum permitted limit for two consecutive years, the monitoring frequency may be reduced to once every two years starting in the following year.) 3 Petagram – World Health Organization total toxicity equivalency quantity/liter (pg-WHO-TEQ/L) B. Substances with potential health impact: 6/13/2017 英譯法規內容 https://oaout.epa.gov.tw/law/PrintEngLawContent.aspx?Type=E&id=171 5/7 Item Maximum limit Unit 1. Flouride (as F-) 0.8 milligrams/liter 2. Nitrate nitrogen 10.0 milligrams/liter 3. Silver 0.05 milligrams/liter 4. Molybdenum (This regulation only applies to water supply systems with a potential pollution source, such as those with semiconductor fabrication plants, optoelectronic manufacturing plants, or parts manufacturing plants, located within a 5-kilometer distance upstream from their water intake. The testing frequency is once per quarter. If the test values do not exceed the maximum permissible limits for two consecutive years, the testing frequency could reduce to once per year from the following year.) 0.07 milligrams/liter 5. Indium (This regulation only applies to water supply systems with a potential pollution source, such as those with semiconductor fabrication plants, optoelectronic manufacturing plants, or parts manufacturing plants, located within a 5-kilometer distance upstream from their water intake The testing frequency is once per quarter. If the test values do not exceed the maximum permissible limits for two consecutive years, the testing frequency could reduce to once per year from the following year.) 0.07 milligrams/liter C. Contaminants that cause aesthetic, cosmetic, and technical effects: Item Maximum limit Unit 1. Iron 0.3 milligrams/liter 2. Manganese 0.05 milligrams/liter 3. Copper 1.0 milligrams/liter 4. Zinc 5.0 milligrams/liter 5. Sulfate (as SO4 2-) 250 milligrams/liter 6/13/2017 英譯法規內容 https://oaout.epa.gov.tw/law/PrintEngLawContent.aspx?Type=E&id=171 6/7 6. Phenols 0.001 milligrams/liter 7. Anionic surface-active agents 0.5 milligrams/liter 8. Chloride (as Cl-) 250 milligrams/liter 9. Ammonia nitrogen 0.1 milligrams/liter 10. Total hardness (as CaCO3) 300 milligrams/liter 11. Total dissolved solids 500 milligrams/liter 12. Aluminum (This regulation concentration is defined as the concentration of total aluminum.) 0.3 0.2 This standard is effective starting on July 1, 2019. (This regulation is not applicable when the turbidity of the water source is over 500 NTU in the period of typhoon landfall warning, and when the turbidity of water source is over 1000 NTU during the three days after the warning is lifted.) milligrams/liter D. Limit range of residual chlorine (Limited to water supply systems using chlorine as disinfectant): Item Limit range Unit Free available residual chlorine 0.2-1.0 milligrams/liter E. Range for pH index (water treated by stationary continuous water supply equipment on public or private premises are not be subjected to this limitation): Item Limit range Unit Hydrogen ion concentration index (pH value) 6.0-8.5 No unit Article4 For tap water, small water treatment facilities, and community-installed public water supply systems, when source water turbidity values exceed 1,500 NTU caused by torrential rains or other natural disasters, the maximum turbidity limit for drinking water may apply to 4 NTU. Drinking water source turbidity testing data in the foregoing paragraph shall be provided by tap water enterprises, small water treatment units or community-installed public water supply units. Article5 For tap water, small water treatment facilities, and community-installed public water supply systems, when source water turbidity values exceed 1,500 NTU caused by torrential rains or other natural disasters, the limit range 6/13/2017 英譯法規內容 https://oaout.epa.gov.tw/law/PrintEngLawContent.aspx?Type=E&id=171 7/7 of free available residual chlorine may apply to follow values (shall apply only to water supply systems that add chlorine disinfectants). Item Limit range Unit Free available residual chlorine 0.2-2.0 milligrams Article6 (Deleted) Article7 Testing methods for each water quality item designated in these Standards shall be designated and officially announced by the central competent authority. Article8 A competent authority that conducts water quality analysis in accordance with these Standards may commission an approved analysis laboratory to assist with analysis. Article9 Unless an implementation date is separately designated, the regulation items in these standards shall take effect on the date of promulgation.

Drinking Water Quality Standards · Nelum