  1. 22 GAR - GEPA DIV. II - WATER CONTROL CH. 12 - INDIVIDUAL WASTEWATER DISPOSAL SYSTEMS REGS. 1997 - P. 1 CHAPTER 12 INDIVIDUAL WASTEWATER DISPOSAL SYSTEM REGULATIONS §12101. Authority. §12102. Purpose. §12103. Definitions. §12104. Non-Availability of Public Sewer. §12105. Private Sewage Disposal System (General) §12106. Permit Application for Wastewater Disposal System. §12107. Capacity of Septic Tanks. §12108. Location and Installation of Sewage Disposal Systems. §12109. Area of Disposal Fields and Seepage Pits. §12110. Septic Tank Design and Construction. (Figure 3 & 3A) §12111. Percolation Tests. §12112. Subsurface Absorption. (Figure 4) §12113. Inspection of Work in Progress. §12114. Stop Work Orders. §12115. Certificate of Occupancy. §12116. Temporary Toilet Facilities. §12117. Cleaning Wastewater System, Disposal of Wastewater, Requirements and Procedures. §12118. Operation and Maintenance. §12119. Appendix A - Sample Design Calculation. §12120. Penalties. NOTE: Rule-making authority cited by Guam Environmental Protection Agency, 10 GCA §45106. These regulations were filed with Legislative Secretary on September 11, 1987. §12101. Authority. (a) Title 10 Chapter 45 §45106 authorizes the Guam Environmental Protection Agency to adopt such regulations as may be necessary to implement Chapter 48, Toilet Facilities and Sewage Disposal, of Title 10. §12102. Purpose. The purpose of these regulations is: (a) Protect the health of the septic tank user and his neighbors. (b) To establish minimum standards that will ensure that wastes discharged: (1) Will not pollute or contaminate the waters of any bathing beach, shellfish breeding grounds, or stream or groundwater source which could be used for public or domestic water supply purposes or for recreational purposes; (2) Will not pose a health hazard by being accessible to children. 22 GAR - GEPA DIV. II - WATER CONTROL CH. 12 - INDIVIDUAL WASTEWATER DISPOSAL SYSTEMS REGS. 1997 - P. 2 (3) Will not give rise to a nuisance due to odor or unsightly appearance; (4) Will not violate any other laws or regulations governing water pollution or sewage disposal. §12103. Definitions. (a) Administrator means the Administrator of Guam Environmental Protection Agency or his duly authorized representative. (b) Individual Sewage Disposal System means a system designed and installed to dispose of sewage from a single building or group of buildings located on one lot. such a system may consist of a septic tank, together with a leaching field or seepage pit, or other treatment unit. (c) Septic Tank means a water tight receptacle which receives the discharge of sewage and is designed and constructed so as to retain solids, digest organic matter through a period of detention, and allow the treated liquids to discharge into a subsurface leaching system. (d) Leaching System means a subsurface system of open-jointed or perforated piping bedded in crushed rock or coral, where septic tank effluent may seep or leach into the surrounding porous soil. (e) Sewage or Wastewater means untreated or insufficiently treated human excreta, food waste disposed of through sewers; wash water; liquid wastes from residences, commercial buildings, agricultural operations, and industrial establishments or other places of assembly, and such diluting water as may have entered the waste disposal system. (f) House Sewer or Building Drain means that part of the lowest piping of a drainage system which receives the discharge all waste lines and other drainage pipes inside the walls of the building except those discharging grease and oil, and conveys it to the building sewer pipe beginning 5 feet outside the building walls. Rain water from roof drains or any source shall not be diverted to the said system. (g) Water of the Territory means all shore waters surrounding Guam, streams, lakes, springs, irrigation system, marshes, water courses, waterways, drainage system, and other bodies of water surface and underground, natural or artificial, publicly or privately owned. 22 GAR - GEPA DIV. II - WATER CONTROL CH. 12 - INDIVIDUAL WASTEWATER DISPOSAL SYSTEMS REGS. 1997 - P. 3 (h) Public Sewer means a common sewage collection system serving more than one lot, directly controlled by public authority. (i) Abutting Property means that property, which lies next to any road, street or easement in which a public sewer is located. The boundary of the private property abutting the sewer need not physically touch the sewer easement so long as that piece of land separating the sewer easement from the abutting property consists of a public right of way, easement, road, or street not owned or controlled by another private owner, so that the abutting property owner would be required to obtain a private easement in order to connect this property with that of the sewer. (j) Cesspool means excavation which receives or is intended to receive untreated sewage and from which the liquid directly seeps or leaches into surrounding porous soil. NO cesspool construction is allowed under this regulations. (k) Adjacent Homeowners means homeowners where residences are adjacent to and abut a road, street or other way or easement on which a sewer is installed. (l) Privy means a structure and excavation for the disposal of human excreta by non- water carriage methods and includes the term pit privy, trench latrine, and bored hole latrine. (m) Single Family Residence means a building designed exclusively for occupancy for one family and containing only one dwelling unit. (n) Duplex means a detached building containing two dwelling units. This is the same definition as found in 21 GCA §61103 for a two-family dwelling. (o) Type 2 means a toilet flushed with water and connected to a septic tank and leaching system. (p) Type 3 means privy type, including pit privy, trench latrine and bored-hole latrine. (q) Agency means Guam Environmental Protection Agency (GEPA). §12104. Non-Availability Of Public Sewer. (a) When public sewer intended to serve any lot or premises is not available in any thoroughfare or right of way abutting such lot or premises, drainage piping from any building or 22 GAR - GEPA DIV. II - WATER CONTROL CH. 12 - INDIVIDUAL WASTEWATER DISPOSAL SYSTEMS REGS. 1997 - P. 4 works shall be connected to an approved private sewage disposal system. (b) The public sewer may be considered as not being available to a single family residence or duplex or any residential building, when such public sewer is located more than two hundred (200) feet away from any proposed single family residential unit or duplex, or any existing residential building on any lot or premises which abuts and is served by such public sewer. The Administrator may grant exemption for a single family residential unit or duplex where a public sewer is less than 200 feet away from the building and such residential building cannot be connected to the public sewer or gravity due to obstructions. Exception may only be granted by the Administration, if the Administrator is convinced that after written findings an exemption will not jeopardized the general public health and welfare. (c) Vertical Alignments - Where public sewer is available to a particular building and sewer location is, (1) more than twenty (20) feet above the lowest floor level of the single family residence or a duplex; or (2) more than fifty (50) feet above the lowest floor level of any other structures, public sewer may be considered as not being available. Exemptions, where the vertical distances between lowest floor level and the sewer is less than 20 feet, may be granted by the Administrator or a single-family residential unit or duplex when by written findings it is determined that the public health and welfare will not be jeopardize. (d) Where water is available from PUAG, but a public sewer is not available, toilet facilities shall be type 2. §12105. Private Sewage Disposal System (General).(a) Where permitted by Section IV of this regulations, a building may be connected to a private sewage disposal system which complies with other provisions set forth in these regulations. The type of system shall be determined on the basis of location, soil porosity, and ground water level and shall be de signed to receive all sanitary sewage from the property. The system, except as otherwise provide, shall consist of a septic tank with effluent discharge into a sub-surface disposal field. (b) Where conditions are such that the above system cannot be expected to function satisfactorily for commercial, agricultural and industrial plumbing systems; 22 GAR - GEPA DIV. II - WATER CONTROL CH. 12 - INDIVIDUAL WASTEWATER DISPOSAL SYSTEMS REGS. 1997 - P. 5 for installations where appreciable amounts of industrial or indigestible waste are produced; for hotels, hospitals, office buildings, schools; for occupancies producing abnormal quantities of sewage or liquid waste; the method of sewage treatment and disposal shall be first approved by the Administrator. Special sewage disposal systems for minor, limited or temporary uses shall be first approved by the Administrator. (c) Disposal systems shall be designed to utilize the absorptive portions of the soil formation. Where the ground water level extends to within twelve (12) feet or less of the ground surface or where the upper soil depth is sufficient and the underlying stratum is rock or impervious soil, septic tank and disposal field system may be installed. (d) All lots served by an on site disposal system shall contain sufficient reserve area which would permit at least 100% replacement of the proposed leach field system. No division of the lot or erection of structures on the lot shall be made if such division or structure impairs the functional usefulness of the designated 100% expansion area. (e) No property shall be improved in excess of its capacity to properly absorb sewage effluent in the quantities and by the means provided in these regulations. (f) When there is insufficient lot area or improper soil conditions for adequate sewage disposal from a building or proposed use of the land as determined by the Administrator, no building permit shall be issued and no private sewage disposal shall be permitted. Where space or soil conditions are critical, no building permit shall be issued until engineering data and test reports satisfactory to the Administrator have been submitted and approved. (g) Where public sewers may be installed at a future date, provisions should be made in the household plumbing system for connection to such sewer upon notification by the Administrator within 5 years period after it is available. (h) New septic tanks, leaching fields, out houses or other on-site sewage disposal systems shall not be permitted within flood hazard areas. All sewage disposal lines shall be connected to government sewage at the developer's expense. Sanitary sewage systems shall be designed to minimize or eliminate infiltration of flood waters into the system and discharges from the systems into flood waters Variances to such standard or procedure 22 GAR - GEPA DIV. II - WATER CONTROL CH. 12 - INDIVIDUAL WASTEWATER DISPOSAL SYSTEMS REGS. 1997 - P. 6 maybe granted through appeal to the Territorial Planning Commission which may grant such variances only upon written findings that applicant satisfied all the criteria outlined granting variances satisfied all the criteria outlined granting variances under 21 GCA §61617. (i) Nothing contained in these regulations shall be construed to prevent the Administrator from requiring compliance with higher requirements are essential to maintain a safe and sanitary condition. (j) No wastewater disposal system installations, constructions, repairs or additions shall be made by the owner of the property without written permit from the Agency. (k) Any person whose application for a permit under these regulations has been denied shall be notified in writing as to the reason for denial and such person may within 15 days after date of official notification, shall file a written request for a hearing before the Agency. Such hearing shall be held by the Agency within 30 days after receipt of the request and upon reasonably notice to the applicant . The Board of Directors of the Agency shall affirm, modify, or revoke the denial, or issue the permit on the basis of the evidence presented at the hearing. (l) The design criteria presented in these regulations can only be applied to systems utilized by residential units up to and including a four-plex dwelling. Systems which must serve larger residential complexes, commercial, or industrial facilities must be based on design criteria specific to the facility. The standard guidance presented within these regulations is not considered adequate for such facilities. (m) Approval of Administrator required. No toilet or sewage facilities or single-family residences subdivisions, apartments, motels, hotels or other multi-housing facilities, commercial buildings, institutions, and industrial facilities, may be constructed without the approval of the Administrator, or put into operation without his inspection and approval. §12106. Permit Application Issuance Procedures and Requirements for Wastewater Disposal Systems. (a) Before specific plans and specifications for individual wastewater disposal system permit application are reviewed for compliance with Guam Environmental 22 GAR - GEPA DIV. II - WATER CONTROL CH. 12 - INDIVIDUAL WASTEWATER DISPOSAL SYSTEMS REGS. 1997 - P. 7 Protection Agency (GEPA) regulations, such plans and specifications shall contain the following as minimum: (1) Vicinity Map - plans must include vicinity map to locate property showing adjacent streets with names and other land marks that can easily locate the property where the proposed improvement is to be established. (2) Plot and Grading Plan (DWG-C-1) - plans must include a plot plan, drawn to scale and completely dimensioned, showing direction and approximate slope of the ground surface, and must contain the following: (A) Delineation of property boundaries, lot number and zone designation; (B) Delineation of public rights of way, easements and access roads, if applicable; (C) Indication of location of all present or proposed or existing retaining walls, drainage channels, water supply lines or walls, drainage channels, water supply lines or walls, paved areas and structures on the plot with relation to lot lines and structures. (D) Location of proposed or existing sewage facilities in relation to property boundaries, public rights of way, easements and access roads, existing structures and utilities, and the proposed building. (E) A description of the complete installation including quality, kind and grade of materials, equipment, construction, workmanship and methods of assembly and installation. (F) A log of soil formation and ground water levels as determined by the test holes dug, in accordance with the requirements of the Administrator, at the location of the proposed leaching system. (G) Topography of the area, showing contour lines and floor elevation of the existing or proposed system. (H) Profile of existing ground and elevations of flowline along sewerline as per cross-section plan drawing (DWG-C-2). (3) Regardless of the type of disposal system applied for, the permit application should bear the 22 GAR - GEPA DIV. II - WATER CONTROL CH. 12 - INDIVIDUAL WASTEWATER DISPOSAL SYSTEMS REGS. 1997 - P. 8 signature of the Public Utility Agency of Guam (PUAG) for water and sewer availability verification and approval for sewer connection if sewers are available and location of connection point. The Department of Land Management must process the plans for verification of property boundary, confirmation of ownership, zoning and itemization Territorial Planning Commission (TPC)/Territorial Sea shore Protection Commission (TSPC) of conditions prior to GEPA review and their signature must be included on the Building Permit Application Form. (A) When a property is within the wet land zone, review and clearance and approval form Land Management, Bureau of Planning, ACOE, Department of Agriculture is required prior to GEPA review and their signature must be included with Building Permit application. (4) Design calculation of the proposed wastewater disposal system is required and the design must be done by a licensed specialty contractor or registered professional engineer. (5) A log of soil formation, percolation and water table tests should be done by a registered professional engineer and such 22 GAR - GEPA DIV. II - WATER CONTROL CH. 12 - INDIVIDUAL WASTEWATER DISPOSAL SYSTEMS REGS. 1997 - P. 9 (6) Complete septic tank and leaching field or aeration tank and leaching field design and construction details must be included in the building plans and specifications. (b) A building permit application form, completely filed out with name(s) and address of applicant, job location, lot, block and tract numbers, and area of lot in square feet or square meters. (c) Three (3) complete sets of building plans, one for the Environmental Protection Agency (EPA) and the other two (2) for distribution to other agencies. (d) Septic Tank Permit Validity - Any septic tank permit shall be void if the work authorized by said permit is not commended with three (3) months after its issuance; or is suspended or abandoned for a period of three (3) months at any time the work has commenced; provided that for just cause stated in writing to the Administrator, the Administrator may allow up to a maximum of three (3) months extension. All such extensions shall be in writing and noted on the septic tank permit and in the individual wastewater records of the Section of Individual Wastewater Program. (e) No building permit or certificate of occupancy under the Building Law of Guam shall be issued without prior compliance with the requirements of the above section. §12107. Capacity of Septic Tanks. (a) The net volume or effective capacity below the flow line of a septic tank, for flows up to 500 gpd, should be at least 750 gallons. For flows between 500 and 1500 gpd, the capacity of the tank should equal to at least 1-1/2 days sewage flow. The liquid capacity and sizes of septic tank as determined by the number of bedrooms or duplex units in any dwelling occupancies shall be as established in Table 1 - "Guidelines for Construction of Septic Tank (Liquid Capacity)". TABLE I Guidelines for Construction of Septic Tank (Liquid Capacity) No. of Recommended Recommended Recommended Bedrooms Sewage Flow* Minimum Tank Minimum Inside No. of (Gallons) (GPD) Capacity Dimension Tank L.W.D. (Gallons) 22 GAR - GEPA DIV. II - WATER CONTROL CH. 12 - INDIVIDUAL WASTEWATER DISPOSAL SYSTEMS REGS. 1997 - P. 10 2 480 750 6' x 4' x 6' 3 720 1,080 7'-6" x 4' x 6' 4 960 1,440 7' x 6' x 6' 5 1,200 1,800 7' x 7' x 6' 6 1,440 2,160 8.5' x 7' x 6' SOURCE: GEPA, Rural Islandwide Facilities Plan, Table 5-2, Page 5-17. Manual of Septic Tank Practice - U.S. Department of Health; Education and Welfare. Public Health Service Publication #526. §12108. Location and Installation of Sewage Disposal System. (a) No part of the system shall be located so that is nearer to any water supply than outlined in Figure 1 and Table II, or so that surface drainage from its location may reach any domestic water supply. The distances given in Figure 1 and Table I are the minimum distances to any water of the territory, property lines, dwelling, school, public building, or a building used for commercial, or industrial purposes or as a place of assembly. (b) Suggested location of tank and disposal field on varying ground slopes (Figure 2). (c) Location shall be such as to provide not less than the stated minimum distances in Table II. TABLE II Minimum Safe Horizontal Distances in Fact To From Privy Septic Absorption Absorption Tank Bed Field 1. Any water of the Territory 300' 300' 300' 2. Any dwelling, school, public building, or a building used for commercia or industrial purpose. 20‘ 10' 20' 20' 3. Property boundary lines. 5' 5' 5' 4. Water lines 10' 5. Wells 300* 300* 300* NOTE: 1. Should there be any legislative amendment to any minimum safe distance requirement, the latest amendment shall govern. 2. No septic tank shall be constructed in a position not easily accessible for emptying or cleaning. 22 GAR - GEPA DIV. II - WATER CONTROL CH. 12 - INDIVIDUAL WASTEWATER DISPOSAL SYSTEMS REGS. 1997 - P. 11 *3. Minimum distances from well to sources of bacterial contamination. §12109. Area of Disposal Fields. The minimum effective absorption area required for disposal in square feet of leachfield bed, shall be predicated on the required size of septic tank for the type of soil percolation rate as established in Table III "Guidelines for Construction of Septic Tank and Leachfield on Guam". §12110. Septic Tank Design and Construction. (Figures 3 and 3A) (a) Septic tank design shall be such as to provide access for cleaning, adequate volume for settling, and for sludge and scum storage. The structural design shall provide for a sound durable tank which will sustain all loads and pressures and will resist corrosion. (b) Location shall be such as to provide not less than the stated distances in Figure 2 and Table II. (c) Liquid capacity shall be based on the number of bedrooms proposed or reasonably anticipated and shall be at least as required in Table I. (1) The liquid depth of the tank or compartment thereof shall be five (5) feet and not more than six (6) feet. A liquid depth greater than six (6) feet shall not be considered in determining tank capacity; (2) No tank or compartment thereof shall have an inside horizontal dimension of less than four 94) feet or 48 inches. Scum storage shall equal 15% of the total liquid depth and shall be measured from the top of the liquid level to the vertical top of the inlet tee and outlet tee excluding the one (1) inch air space at the top of the tank. In no case shall this area be less than seven (7) inches; (3) The vertical leg of the inlet tee shall not be less than six (6) inches below the liquid surface and above the liquid surface as required in (c)(2) above. (d) Inlet and outlet connections shall be submerged so as to obtain effective retention of scum and sludge. The inlet invert shall be at least three (3) inches above the outlet invert. Access to both inlet and outlet connections shall be provided through manholes or inspection ports. 22 GAR - GEPA DIV. II - WATER CONTROL CH. 12 - INDIVIDUAL WASTEWATER DISPOSAL SYSTEMS REGS. 1997 - P. 12 (e) The vertical leg of the outlet tee shall extend upward to within 1 inch of the underside of the cover and downward to a point which is 40% of the liquid depth below the liquid surface. When a partition wall is used to subdivide the tank, it shall have a 4 inch diameter minimum opening, with the same invert elevation as the tank outlet (See Figure 3A). The partition wall opening shall have an outlet device equivalent to the tank inlet or outlet, so that outside air can enter both sides of the partition. (f) When multi-compartment tanks are used, the volume of the first compartment shall be equal to or greater than that of any compartment. (g) Access to each compartment of the tank shall be provided by a 18" x 18" minimum man hole or removal cover. The inlet and outlet tee connections shall also be accessible through properly placed manholes, handholes or by easily removed covers. (h) Where the top of the septic tank is below ground grade level, manholes shall be built up to ground grade level. (i) The wall of the tank shall not be less than 4 inches thick reinforced concrete poured in place, or less than 8 inches thick load bearing concrete hollow block reinforced at every 16" on center laid on a solid foundation and mortar joints well filled plastered with 1/2 inch concrete mortar in the inside of the tank. The tank covers and floor slabs shall be not less than 4 inch thick reinforced concrete. Septic tank covers may either be poured-in- place or pre-cast. The minimum compressive strength of any concrete septic tank wall, top and covers, or floor shall not be less than 2500 psi (pound per square inch). (j) All septic tanks covers shall be capable of supporting an earth load of not less than 300 pounds per square foot where the maximum coverage does not exceed three (3) feet. (k) After the completion of the septic tank, the inside shall be cleaned and all forms removed, before occupancy permits will be issued. §12111. Percolation Tests. (a) Individual residences. The absorption areas for disposal field and seepage pits for individual residences whenever 22 GAR - GEPA DIV. II - WATER CONTROL CH. 12 - INDIVIDUAL WASTEWATER DISPOSAL SYSTEMS REGS. 1997 - P. 13 applicable shall be computed or determined from Table III when sufficient information about area soils is available. (b) All proposed site shall be subjected to percolation tests acceptable to the Administrator if it is determined that insufficient information exists concerning the permeability characteristics of soils within the proposed site. (1) For individual lots, one (1) percolation test per lot is required as a minimum, and shall be performed at the location of the proposed field. Where the soil is not uniform or there is more than one type of soil on the lot, on percolation test is required as a minimum at the center of each variation or type of soil that exists within the disposal field area. (2) For subdivisions or multiple lots, a sufficient number of percolation tests must be performed to determine the general acceptability of the area. Final disposal field size must be based on a minimum of one test per site. (c) Test Procedure (Figure 5) All percolation tests required should be performed in accordance with the following: (1) Dig or bore the holes with horizontal dimensions from 4 to 12 inches and vertical sides to the depth of the bottom of the pro posed absorption device. Holes can be bored with 4 inch diameter post hole type auger. (2) Roughen or scratch the bottom and sides of the holes to provide a natural surface. Remove all loose materials from the hole. Place about 2 inches of coarse sand or fine gravel in the hole to prevent bottom scouring. (3) Fill the hole with clear water to a minimum depth of 12 inches over the gravel. By refilling, or by supplying a surplus reservoir of water (automatic siphon), keep water in hole for at least four hours, and preferably overnight. In granular soils, i.e., GW, GP, SW, or SP classified according to the Unified Soils Classification System," the test can be made after the water from one filling has seeped away. 22 GAR - GEPA DIV. II - WATER CONTROL CH. 12 - INDIVIDUAL WASTEWATER DISPOSAL SYSTEMS REGS. 1997 - P. 14 (4) Percolation rate measurements should be made on the day following the saturation process, except in sandy soils. (5) If water remains in the test hole after overnight saturation, adjust the depth to 6 inches over the gravel. From a fixed reference point, measure the drop in water level at approximately 30-minute intervals over a 4-hour period. The drop which occurs during the final 30-minute period is used to calculate the percolation rate. It must be noted that if a soil or site is determined to be poorly drained with an accompanying high water table, it is unsuitable regardless of percolation test data. (6) If no water remains in the hole after overnight saturation, add clear water to a depth of about six inches over the gravel. From a fixed reference point, measure the height of the water surface at approximately 30 minutes intervals over a 4-hour period, refilling the hole to a depth of six inches when the percolation rate indicates the hole will run dry before the next reading is made. The drop which occurs during the final 30-minute period is used to calculate the percolation rate. It should be noted that if a hole must be refilled to obtain a final 30-minute reading, determine from the previous reading the water level drop during that interval add water until the level above the bottom equals this figure plus one half inch. Continue the test, measuring the drop during the final 30-minute period. (7) In sandy soils, or other soils in which the first six (6) inches of water seeps away in less than 30 minutes, after the overnight saturation period, the time interval between measurements can be taken as 10 minutes and the test run over a period of one hour. The drop which occurs in the final 10-minute period is used to calculate the percolation rate. §12112. Subsurface Absorption Field. (a) Bed Construction (Figure 4) Where percolation rates are faster than 1" per 30 minutes and soil characteristics and site conditions are acceptable to the Administrator, an absorption bed system may be installed. (b) Trench Construction (Figure 5) Where percolation rates are 1" per 30 minutes or slower but 22 GAR - GEPA DIV. II - WATER CONTROL CH. 12 - INDIVIDUAL WASTEWATER DISPOSAL SYSTEMS REGS. 1997 - P. 15 faster than 1" per 60 minutes and all other soil conditions and site characteristics are acceptable to the Administrator, an absorption trench system must be installed. Minimum required absorption areas are given in Table III. For a bed type system this represents the floor area of the bed. For a trench type system this represents the bottom area of the trench. The standard trench width is three feet. TABLE III GUIDELINES FOR CONSTRUCTION OF SEPTIC TANK AND LEACHFIELD ON GUAM Required Number of Wastewater Septic Tank Percolation Absorption Bedrooms Flow (gpd) Capacity (gal) Test Rate Area (SF) 1" - 5 min 250 1" - 10 min 330 2 480 750 1" - 15 min 380 1" - 30 min 500 1" - 45 min 600 1" - 60 min 800 1" - 5 min 328 1" - 10 min 450 3 750 1080 1" - 15 min 545 1" - 30 min 800 1" - 45 min 900 1" - 60 min 1200 1" - 5 min 436 1" - 10 min 600 4 960 1440 1" - 15 min 738 1" - 30 min 1070 1" - 45 min 1200 1" - 60 min 1600 1" - 5 min 545 1" - 10 min 750 5 1200 1800 1" - 15 min 924 1" - 30 min 1340 1" - 45 min 1500 1" - 60 min 2000 22 GAR - GEPA DIV. II - WATER CONTROL CH. 12 - INDIVIDUAL WASTEWATER DISPOSAL SYSTEMS REGS. 1997 - P. 16 1" - 5 min 660 1" - 10 min 900 6 1440 2160 1" - 15 min 1100 1" - 30 min 1600 1" - 45 min 1800 1" - 60 min 2400 SOURCE: GEPA, Rural Islandwide Facilities Plan, Table 5-2, Page 5-17. (c) Subsurface leaching system, if found to be applicable by percolation test, should be designed and constructed in accordance with Table III and III-A, and the following items: (1) The minimum distances given below shall be used when determining where the disposal field can be located: (A) Sources of domestic water applies 300 ft. (B) Water of the territory------------------------300 ft. (C) Dwellings (i) Septic tank------------ 10 ft. (ii) Leaching System---- 20 ft. (iii) Privy------------------ 20 ft. (D) Property lines---------------------------------- 5 ft. (E) Wells------------------------------------------ 300 ft. NOTE: When existing wells are involved or exceptionally coarse soil formations are encountered, the 300 foot-distance from any water supply shall be evaluated and separations maintained in accordance with the recommendations of the Administrator. (d) Construction of a leachfield in filled ground is not acceptable. 22 GAR - GEPA DIV. II - WATER CONTROL CH. 12 - INDIVIDUAL WASTEWATER DISPOSAL SYSTEMS REGS. 1997 - P. 17 (1) All leaching fields shall be constructed within the following standards: TABLE IV SUBSURFACE LEACHING FIELD CONSTRUCTION DETAILS Bed Trench Item Unit Max. Min. Max. Min. Number of Distribution Drain lines ---- 7 2 8 2 Distance from drain line along perimeter of leachbed feet 3 3 1½ Length of Leach Field feet 100 21 100' Width of Leach Field feet 50 12 3' 3' Depth of Leach Field Bottom inches 48 24 48 24 Depth of coarse material: Under pipe (Min.) inches 6 6 Over pipe (Min.) inches 2 2 Total (Min) inches 12 12 Size of coarse material inches 2½ 3/4 2½ 3/4 Depth of backfill over coarse material inches 36 12 36 12 Distance bet. drain lines center to center feet 6 -- -- 6 (Exception to the above table may be made by GEPA when Soil conditions warrant.) (e) Distribution drain lines shall be constructed of perforated PVC pipes or perforated clay pipes or other approved materials may be used, provided that sufficient openings are available for distribution drain lines of the effluent into the leach bed area. (f) Before placing filter material or drain lines in a prepared excavation, all smeared or compacted surfaces shall be removed from leaching bed area by raking to a depth of 1-inch and the loose material removed. Clean stone, gravel slag or similar filter material acceptable to the Administrator, varying in sizes from 3/4" to 2-1/2" shall be placed in the trench to the depth and grade required in Table IV and Figure 4 and Figures 5, 5A and 5B. Drain lines shall then be covered with filter material to the minimum depth required on Table IV 22 GAR - GEPA DIV. II - WATER CONTROL CH. 12 - INDIVIDUAL WASTEWATER DISPOSAL SYSTEMS REGS. 1997 - P. 18 and the entire bed or trench area covered with untreated building paper, straw, or similar porous material which will prevent closure of voids within the gravel fill. No earth backfill shall be placed over the filter material cover until after inspection and acceptance by the Administrator or his authorized representative. (g) Connections between a septic tank and main distribution line shall be laid with approved pipe with water tight joints on natural ground or compacted fill. (h) Disposal or leaching field shall be constructed as follows: Bed Trench Minimum number of drain lines 21 feet 4 Maximum length of each line 100 feet 100' Minimum bottom width of leachfield 12 feet 3' Maximum bottom width of leachfield 50 feet 3' Minimum bottom width of leachfield 21 feet 3 Maximum bottom length of leachfield 103 feet 103' Minimum spacing of drain lines 6 feet 6' center to center Preferred depth of cover of lines 24 inches 24" Minimum depth of earth cover over lines 12 inches 12" Minimum filter material under drain lines 6 inches 6" Minimum Total Filter Material 12 inches 12" *Maximum grade of lines 6 inches 100" *Minimum grade of lines 3 inches 100" NOTE: When perforated pipe is used, it shall be laid level and with the end of the line capped. Where leaching beds are permitted, distribution drain lines in leaching beds shall not be more than six (6) feet apart on centers and no part of the perimeter of the leaching bed shall be more than three (3) feet form a distribution drain line. When necessary on sloping ground to prevent excessive line slope, leach lines or leach beds shall be stepped. The lines between each horizontal section shall be made with watertight joints and shall be utilized to the maximum capacity before the effluent shall pass to the next lower leach line or bed. The lines between each horizontal leaching section shall be made with approved watertight joints. §12113. Inspection of Work in Progress. The project shall be inspected on regular basis by inspectors from the Guam Environmental Protection Agency (GEPA) to assure that construction of septic tanks and leaching systems or grease trap are in compliance with approved plans and specifications, and in accordance with the Guam Environmental Protection Agency regulations. NOTE: In accordance with GEPA standards: 22 GAR - GEPA DIV. II - WATER CONTROL CH. 12 - INDIVIDUAL WASTEWATER DISPOSAL SYSTEMS REGS. 1997 - P. 19 (a) Schedule of concrete pouring must be made twenty-four hours in advance and work must be performed in the presence of an Environmental Inspector. (b) Inspection before covering. No cover shall be placed over any septic tank, until the depth and other interior dimensions of such septic tank, have been inspected and approved by the Administrator. (c) It shall be the duty of the permit holders pursuant to this regulation to notify the Agency issuing the permit when (a) and/ or (b) above are ready for inspection. Failure to comply with the above requirements may result in unnecessary delays to the project or a suspension of work or denial of a Certificate of Occupancy and an order to remove portions or all of the offending structures. After completion of the project, final inspection by a GEPA inspector shall be conducted on septic tanks and leaching systems to assure that the work is in accordance with the approved plans and specifications and that GEPA requirements are met. §12114. Stop Work Orders. In the event a project is commenced without a septic tank and leaching system permit, or work performed is not in accordance with approved plans and specifications or any approved changes or revisions thereto, or unsafe construction practices are continued after sufficient warnings by the Administrator or his authorized representatives, a STOP WORK ORDER shall be issued and take effect until the conflict is resolved. §12115. Certificate of Occupancy. After final inspection of the septic tank and leaching system indicates that the work per formed was done in accordance with approved plans and specifications and has met all GEPA requirements, the Administrator or his authorized representative shall issue a Certificate of Occupancy. §12116. Temporary Toilet Facilities. (TIF) (a) Temporary Toilet Facilities (TIF) shall be provided for: (1) any construction job-site where working toilets connected to an approved type sanitary disposal system are determined to be not readily available for the needs of the employees. (A) The number of facilities required, whether permanent, temporary or combination thereof 22 GAR - GEPA DIV. II - WATER CONTROL CH. 12 - INDIVIDUAL WASTEWATER DISPOSAL SYSTEMS REGS. 1997 - P. 20 shall be in accordance with the requirements detailed in Table VI. (B) The term readily available as used in item (i) above, shall be defined as being within 300 feet of the work area. Facilities which are within this distance but are not under the director control of the developer/contractor shall require a written authorization/certification from the owner of such facilities that unrestricted access to these toilet facilities will be available to the contractors workers for the entire period of the construction project. (C) All arrangements for sanitary facilities must be made and in place before any clearing or construction may proceed. (2) any carnival, fair, sporting event, outdoor concert or large public gathering requiring a permit, hereafter, collectively referred to as a "special event", where adequate working toilet facilities connected to a sanitary sewer does not exist. Adequacy shall be determined from the Table VII - Toilet Receptacles Required for Special Events. (b) Temporary Toilet Facilities may be chemical, recirculating or combustion providing they comply with existing Guam Codes. (c) The minimum number of TIF required for construction site shall be based in accordance with Table VI below: (i) Table VI - Number of TIF required for construction sites Number of Employees Minimum Number of Units 1 to 15 1 16 to 30 2 31 to 51 3 52 to 72 4 73 to 93 5 Over 93 1 Add'l unit/20 employees (ii) The minimum number of temporary toilet receptacles at any special even shall be in accordance with Table VII below: TABLE VII Toilet Receptacles Required for Special Events (Minimum) Number of Hours 22 GAR - GEPA DIV. II - WATER CONTROL CH. 12 - INDIVIDUAL WASTEWATER DISPOSAL SYSTEMS REGS. 1997 - P. 21 1 2 3 4 5 6 7 8 9 10 1,000 or below 1 1 1 2 2 2 3 3 3 4 2,000 1 2 2 3 4 4 5 6 6 7 3,000 1 2 3 4 5 6 7 8 9 10 4,000 2 3 4 6 7 8 9 12 12 14 5,000 2 4 5 7 9 10 12 15 17 19 6,000 2 4 6 8 10 12 14 16 18 20 7,000 3 5 7 10 12 14 17 19 21 24 8,000 3 6 8 11 14 16 19 22 24 27 9,000 3 6 9 12 15 18 21 24 27 30 10,000 4 7 10 14 17 20 24 27 30 34 Ref. Satellite Industries of Minneapolis, Minn. Portable Sanitation Unit Calculator for Special Events. (d) Any construction site or special even requiring GEPA approval for permitting will provide proof that the minimum required number of toilet facilities are available or will be avail able for the period of time that the permits are valid. (e) Failure to comply (i) Any construction site not complying with the minimum number of TIF will be given a written warning and given 48 hours to comply. Failure to comply within the given period will result in the revocation of the GEPA approval required for the building permit which will temporarily suspended all construction at this site. (ii) Any special event not meeting the minimum number of TTF will have its permit to operate immediately suspended. §12117. Cleaning Wastewater System, Disposal of Wastewater, Requirements and Procedures. (a) No person shall engage in the business of cleaning individual sewage disposal system or disposing of the waste therefrom unless; a business license has been secured from the Department of Revenue and Taxation, and Registration has been issued to him by the administrator. Such business shall be conducted in 22 GAR - GEPA DIV. II - WATER CONTROL CH. 12 - INDIVIDUAL WASTEWATER DISPOSAL SYSTEMS REGS. 1997 - P. 22 conformity with the following requirements and in accordance with the regulations. (1) The name and address of the person, shall be legibly lettered on both sides of each vehicle used for cleaning purposes. (2) Every vehicle used for cleaning purposes shall be equipped with a watertight tank or body and be maintained in a clean and sanitary condition. Sewage waste shall not be transported in an open body vehicle. (3) All portable receptacles used for transporting liquid or solid waste shall be watertight, equipped with tight-fitting lids, and shall be cleaned daily. (4) All pumps and hose lines shall be properly maintained so as to prevent leakage. (5) Approval in writing shall be obtained from the Administrator for every site at which the person plans to discharge the waste material collected. The approval may be given after consultation with Public Utility Agency of Guam. (6) The hose or any similar devise used for discharging waste must be inserted into the earmarked manhole to a depth of approximately two (2) feet, to prevent any spray or spillage into the surrounding area. (7) Every precaution must be taken to prevent any public nuisance or health hazard which may be caused by their service. (b) Registration shall be issued to any person properly making application therefor, who is not less than twenty-one (21) years of age, has successfully demonstrated the ability to handle the equipment, and only after the place or places and manner of disposal of the cleaning proposed by said applicant are approved by the Administrator. (c) Registration issued pursuant to these Regulations is not transferable and shall expire December 30th of each year. A Registration may be renewed for an ensuing year by making application for renewal of the registration, upon determination of the applicant's observance of sanitary laws, ordinance, and directions. Such application shall have the effect of extending the validity of the current registration until 22 GAR - GEPA DIV. II - WATER CONTROL CH. 12 - INDIVIDUAL WASTEWATER DISPOSAL SYSTEMS REGS. 1997 - P. 23 a new registration is received or the applicant is notified by the Administrator that the renewal of the registration has been refused. (d) All persons, who are registered to clean individual sewage disposal system, i.e., holding tank etc. or to dispose of the wastewater there from, shall file with the Administrator a statement giving the name and the address of the owner or tenant of each and every one of the premises where an individual sewage disposal system has been cleaned by said registrant, or his employer, or by others on his behalf. The report must be submitted on a monthly basis, covering a 4 weeks period. (e) Non-compliance of the requirements of these requirements of these regulations may result in the revocation of suspension of the applicant's registration. Any applicant whose registration is suspended must correct all discrepancies noted in the suspension within 30 days, otherwise his registration may be revoked. (f) Registration under these regulations shall not be construed as impairing in any manner, the existing powers and duties of the Department of Public Health and Social Services, Public Utility Agency of Guam, Department of Public Safety, Department of Revenue and Taxation, and Department of Commerce under other laws. §12118. Maintenance. (a) Maintenance of septic tanks and leaching fields shall be the responsibility of the owner, lessee, occupant, or person in possession of property, unless mutually agreeable arrangements are made with a private company. (b) Owners of septic tanks shall empty and clean the tank or pit when necessary, or when ordered by the Administrator in the interest of public health, and the contents disposed of in such place and manner as shall be authorized by the Administrator. (c) Septic Tanks should be inspected by the owner at intervals of no more than 3 years to determine the rates of scum and sludge accumulation. The inlet and outlet structures and key joints should be inspected for damage after each pump-out. (d) The tank should be cleaned whenever: 22 GAR - GEPA DIV. II - WATER CONTROL CH. 12 - INDIVIDUAL WASTEWATER DISPOSAL SYSTEMS REGS. 1997 - P. 24 (1) the bottom of the scum layer is within 3 inches of the bottom of the outlet device; (2) the sludge level is within 8 in. of the bottom of the outlet device. (e) Septic tank sludge and Temporary Toilet Sludge shall be disposed of by hauling to a sewage treatment facility. If for some unique reason disposal cannot be done at an approved facility land spreading of waste may be considered on a specific case by case basis. The specifics of each request will be evaluated separately and a permit obtained from GEPA for each separate request. Any such disposal can only take place after review and approval by the Administrator and only done under the direct supervision of GEPA staff. (f) In order to be effective, grease traps must be operated properly and cleaned regularly to prevent the escape of appreciable quantities of grease. The frequency of cleaning at any given installation can best be determined by experience based on observation. Generally, cleaning should be done when 75% of the grease- retention capacity has been reached. At restaurants, pumping frequencies range from once a week to once every 2 or 3 months. §12119. Appendix A - Sample Design Illustration. (a) Flow Estimate Given: 3 BR House with washing machine and garbage grinder 2 persons per bedroom 75 gallons per person per day Additional: 40% of flow for washing machine 20% of flow or garbage grinder Flow: 3BR x 2 person/Br x 75 gal/person/Day = 450 gallons/day Total Flow:450 + 40% (450) + 20% (450) 450 + 60% (450) 450 + 270 = 720 gallons/day (b) Septic Tank Design - (Three Bedroom House) V = Total flow + 50% (total flow) (provision for detention period for treatment inside septic tank) V = 720 + 50% (720) 22 GAR - GEPA DIV. II - WATER CONTROL CH. 12 - INDIVIDUAL WASTEWATER DISPOSAL SYSTEMS REGS. 1997 - P. 25 = 720 + 360 = 1080 ga 7.48 gal/cu.ft. = 144.3 cubic feet Depth = 5'-0" + 1'-0" Air Space Try Width = 4'-0" Therefore length = 144 = 7.22' say 7'-6" 5x4 Septic Tank Dimension = 7‘-6“ x 4'W x 5'D Volume = 7'-6" x 4' x 5' = 150 cu. ft. 150 144 Check: 1.5 L 2.5 L ration = 1.88 W W Adopt Septic Tank Dimension = 7'-6" x 4'W x 6'D (c) Absorption Area: (Three Bedroom) Total Flow = 720 gallons Say percolation rate of 1" - 15 minutes 720 = 545 sq. ft. 1.3 Actual percolation rate determined by testing. (1) Leaching Field: Note: (Separation of Leaching Pipe shall be 6 ft. on center) Say Width = 18'-0' Length = 545 = 30.2 ft. say 31 feet 18 Therefore length field size = 18'W x 31'L §12120. Penalty. (a) person who violates any provisions of this regulations or who refuses or neglects to comply with any lawful order issued by the Administrator shall be guilty of misdemeanor and subject to a fine not to exceed $1,000.00. each day of violation shall constitute a separate offense (10 GCA §48126). (b) Any penalty imposed pursuant to sub- section (a) of this Section shall not be bar to enforcement of this Chapter or the rules and regulations in force pursuant thereto or orders made pursuant to this Chapter by injunction or other remedy, to institute and 22 GAR - GEPA DIV. II - WATER CONTROL CH. 12 - INDIVIDUAL WASTEWATER DISPOSAL SYSTEMS REGS. 1997 - P. 26 maintain in the name of territory all such enforcement proceedings (10 GCA §48126(b)).

Individual Wastewater Disposal System Regulations - Chapter 12 of Title 22 of the Guam Administrative Rules and Regulations · Nelum