Skip to content
Nelum
Laws of United Arab Emirates

dubai administrative resolution no 13 of 2025 preventive system manual (from the file; to confirm against the document)

Text as of 2026-09-30

Public law and official guidance, published as research. Not legal, tax or financial advice.

About this law

Kind
Order
Number
to confirm
Issued by
to confirm
Country
United Arab Emirates

Where to read it

Text

The law's own text, section by section, as held. Each section has its own link.

  1. Article (1) a. Pursuant to this Resolution, the attached Preventive Systems Manual, inclusive of the requirements and technical standards set forth therein, is approved. b. The Security Industry Regulatory Agency must publish the Manual approved pursuant to paragraph (a) of this Article, together with any amendments thereto, on its website. Scope of Application

  2. Article (2) The Manual approved under this Resolution applies to all establishments specified in the above-mentioned Board of Directors Resolution No. (1) of 2018. ©2025 The Supreme Legislation Committee in the Emirate of Dubai 1 Every effort has been made to produce an accurate and complete English version of this legislation. However, for the purpose of its interpretation and application, reference must be made to the original Arabic text. In case of conflict, the Arabic text will prevail. Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 1 of 140 Repeals

  3. Article (3) Any provision in any other administrative resolution or manual is hereby repealed to the extent that it contradicts the provisions of this Resolution or the Manual attached hereto. Publication and Commencement

  4. Article (4) This Resolution will be published in the Official Gazette and will come into force on the day on which it is published. Khalifa Ibrahim Al Saleis Chief Executive Officer Security Industry Regulatory Agency Issued in Dubai on 14 April 2025 Corresponding to 16 Shawwal 1446 A.H. Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 2 of 140 Contents Definitions .................................................................................................... 6 Part One: Technical Specifications and Controls ............................................... 7 Chapter One: Digital Systems Specifications (IP) .............................................. 8 Chapter Two: Specifications of Access Control Systems .................................. 15 Chapter Three: Specifications for Alarm and Intruder Detection Systems.......... 17 Chapter Four: Locks Specifications ................................................................ 20 Chapter Five: Specifications of Penetration-Resistant Glass ............................. 20 Chapter Six: HVM Barriers Specifications (External Perimeter Safety) ............... 20 Part Two: Operational Controls ..................................................................... 22 Chapter One: Operational Image Requirements ............................................. 24 Chapter Two: Remote Communication Requirements ..................................... 27 Chapter Three: Management and Operation .................................................. 27 Chapter Four: Security Lighting .................................................................... 28 Chapter Five: Image Acceptance .................................................................. 28 Chapter Six: The Sustainability of Security Systems ........................................ 29 Chapter Seven: Maintenance, Development and Modification of Security Systems ..................................................................................................... 31 Chapter Eight: Prohibitions ........................................................................... 32 Chapter Nine: Exceptional Cases................................................................... 32 Chapter Ten: Quality of Work and Installation................................................ 33 Part Three: Security Requirements and Conditions ......................................... 34 Chapter One: Security Conditions and Requirements for Luxury Hotels: ........... 35 Chapter Two: Security Conditions and Requirements for Tourist Hotels: ........... 38 Chapter Three: Security Conditions and Requirements for Shopping Malls: ....... 41 Chapter Four: Security Conditions and Requirements for Important Complexes: 44 Chapter Five: Security Requirements for Labor Accommodations: .................... 55 Chapter Six: Security Conditions and Requirements for Cinemas and Theaters: 57 Chapter Seven: Security Conditions and Requirements for Amusement Parks: .. 59 Chapter Eight: Security Conditions and Requirements for Educational Facilities: 61 Chapter Nine: Security Requirements for Healthcare Facilities: ........................ 66 Chapter Ten: Security Requirements for Non-Muslim Places of Worship: .......... 69 Preventive Systems Manual (Translated by SIRA) Page 3 of 140 Chapter Eleven: Security Requirements for the Manufacture and Sale of Precious Metals and Gemstones:................................................................................ 70 Chapter Twelve: Security Requirements for Financial and Monetary Institutions: ................................................................................................ 76 Chapter Thirteen: Security Requirements for Sports and Recreational Halls and Clubs: ........................................................................................................ 88 Chapter Fourteen: Security Requirements for Gas Stations: ............................ 89 Chapter Fifteen: Security Requirements for Large and diverse Stores:.............. 90 Chapter Sixteen: Security Requirements for Electronic Games and Entertainment Halls and Arenas: ........................................................................................ 94 Chapter Seventeen: Security Requirements for Football Clubs: ........................ 96 Chapter Eighteen: Security Requirements for Warehouse compounds: ............. 98 Chapter Nineteen: Security Requirements for Warehouses: ............................. 99 Chapter Twenty: Security Requirements for Self-storage: ..............................102 Chapter Twenty-One: Security Requirements for Air Cargo: ...........................107 Chapter Twenty-Two: Security Requirements for Factories: ...........................109 Chapter Twenty-Three: Security Requirements for Vacation Homes: ...............112 Chapter Twenty-Four: Security Requirements for Shooting Ranges: ................113 Chapter Twenty-Five: Security Requirements for Art Galleries: .......................114 Chapter Twenty-Six: Security Requirements for Vehicle Rental Shops: ............116 Chapter Twenty-Seven: Security Requirements for Tobacco Retail Stores: ......117 Chapter Twenty-Eight: Security Requirements for Precious Goods Stores: .......118 Chapter Twenty-Nine: Security Requirements for Data Centers: .....................120 Chapter Thirty: Security Requirements for Pharmacies: .................................122 Chapter Thirty-One: Security Requirements for Massage Centers: ..................123 Chapter Thirty-Two: Security Requirements for Parking Rental and Management Services: ...................................................................................................124 Chapter Thirty-Three: Security Requirements for Auction Halls:......................125 Chapter Thirty-Four: Security Requirements for Customer Happiness Centers:.126 Chapter Thirty-Five: Security Requirements for Business Centers: ..................127 Chapter Thirty-Six: Security Requirements and Conditions for Quran Memorization Centers and Islamic Institutions: .............................................128 Chapter Thirty-Seven: Security Requirements for Charitable Organizations: .....130 Chapter Thirty-Eight: Security Requirements for Hunting Equipment Stores: ...132 Chapter Thirty-Nine: Security Requirements and Conditions for the Security Monitoring Operations Center: .....................................................................133 Chapter Forty: Security Requirements for the Transport of Money and Valuable Materials: ..................................................................................................135 Chapter Forty-One: Security Requirements for Vehicle safety and Protection: ..138 Chapter Forty-Two: Security Requirements for Transfer and Delivery of Preventive Systems Manual (Translated by SIRA) Page 4 of 140 Money: ......................................................................................................139 Chapter Forty-Three: Communication and Communicating Requirements for Security guard Service Providers:.................................................................140 Preventive Systems Manual (Translated by SIRA) Page 5 of 140 Definitions SN Term Definition It includes vital sectors, important complexes and the like, specified in accordance with the provisions of the 1 Establishment Executive Regulations of Law No. (12) of 2016 regarding the regulation of the security industry in the Emirate of Dubai. Establishment All entrances and exits to the establishment, including 2 Entrances emergency exits. All corridors which are used by visitors or residents of Establishment 3 residential buildings, including internal and external Corridors service corridors in the establishment. Cash and Includes all reception, service, assistance and cash desks 4 Reception in the establishment. Counters 5 Stores the facilities used for storage. the facilities that include multiple warehouses designated 6 Warehouses for storage. Vehicle include all entrances and exits designated for vehicle 7 Entrances movement into the establishment or its annexes. Camera View The visual range that is covered by the camera and 8 Range (Field of displayed on the surveillance screen. view) The object's visibility scale at a height of 1.6 meters, 9 Standard Target represented by a human body or a standard test target. Image Element 10 Density (Pixel The pixel count per meter at the standard target. Density) Vehicle License Plate View The visibility of a vehicle license plate measuring 330 x 11 Range (Number 160 mm. Plate Recognition) The range used to analyze facial expressions of individuals 12 Inspection View (targets), where the face must be the most prominent element in the image. The identification visibility range is the range used to Identification 13 identify previously unknown individuals (targets) upon View entering the establishment. Recognition It is used to identify and track previously identified 14 View individuals (targets). Observation It is used to control and direct crowds, gatherings, and 15 View public events. It is used to detect basic features such as the nature of 16 Detection View movement, direction, and general appearance. It is used to detect the presence of targets without 17 Monitoring View recognition for early warning purposes. Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 6 of 140 Part One: Technical Specifications and Controls Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 7 of 140 Chapter One: Digital Systems Specifications (IP) First: Cameras SN Specifications Remarks 1 They must be in color. - The camera resolution must be at least 1080p Full 2 - HD. The variable bit rate feature must be enabled, 3 without using a fixed bit rate and without specifying - a maximum speed. They must be compatible with all the standard security system management software available on 4 - the market or capable of direct connection to known standard systems. 5 The signal-to-noise ratio must be at least 48 dB. - 6 The cameras must be clearly visible and not hidden. - The cameras must be designed and manufactured 7 - to operate continuously without interruption. Cameras or enclosures for outdoor use must have a 8 rating of at least IP66 to ensure continuous - operation in an outdoor environment A Dynamic Wide Range (WDR) is required for any camera facing a natural or artificial light source, 9 - direct or reflected from polished surfaces, and the WDR must be at least 110 dB or equivalent Auto Iris feature must be used for locations where 10 - lighting varies according to the time of day. Infrared (IR) light is required, with the ability to 11 automatically switch to monochrome night - photography when visible light fades. Cameras installed at height of 4 meters and above 12 - shall have remote zoom and focus ability. Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 8 of 140 Second: Recording devices A. General Specifications: SN Specifications Remarks 1 Only digital recording devices must be used - 2 The recording resolution must be at least 1080p Full - HD. 3 The live view resolution must be at least 1080p Full HD - for single-camera viewing, and at least 2 CIF per camera for multiple-screen viewing. 4 It must be capable of performing the three basic - functions simultaneously: (1) live view, (2) recording, and (3) playback of previous recordings, without any degraded or negatively impacted performance of any of these functions. 5 Live view must be at least 25 frames per second for - each camera. 6 A copy feature must be provided for some or all the - recorded clips, for any required duration, whether for a single camera, a group, or all cameras connected to the recording device, and for transferring them to standard storage media. The copy format must also be standard so that it can be viewed on standard display media. 7 The maximum recording transfer time should be 1/10 - of the duration of displaying the same recording at normal speed. 8 Effective and efficient search methods must be - provided to facilitate access to the desired scenes. These include a combined search for both date and time, specifying the cameras included in the search, displaying search results for all included cameras sequentially, and providing fast and slow playback, as well as both forward and reverse playback. 9 Both continuous and non-continuous recording must be - available. (Non-continuous recording is associated with a specific event, such as motion or a signal from an external device, such as intruder detection system sensors.) In the case of non-continuous recording, the device must be capable of recording scenes before and after the event, lasting at least ten (10) seconds. These features must be available so that they can be activated for all cameras connected to the recording device individually (i.e., they can be activated for each camera separately). 10 Minimum non-continuous motion-activated recording - setting: No less than 70% of the day for each camera, no less than 10 frames per second for each camera, and no Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 9 of 140 less than 31 days 11 The recording devices must be computed with 20% - extra capacity. 12 The device must accept the addition of peripheral - storage devices to increase the total storage capacity. 13 The device must be able to clearly display the camera - name and the actual time and date without obscuring the view. (The system should preferably accept Arabic letters.) The camera name must be expressive and descriptive of the location the camera is monitoring and must not be ambiguous symbols with no linguistic meaning. 14 The device shall have effective feature of automatic - self-recording in case of restarting the device after shutdown for whatever reason (mistake, servicing, maintenance, or system fault... etc.). Such features shall be effective even if the device has not shutdown properly. 15 The variable bit rate feature must be enabled only, - without specifying a maximum transfer speed. Fixed bitrate data transfer speeds are not accepted. 16 Software Development Kit (SDK) shall be made - available and to be provided to SIRA upon request. 17 It shall be compatible with ONVIF 2.0 standards. - 18 It shall support live streaming through the Real Time - Streaming Protocol (RTSP). 19 It shall support the Central Time feature (Network - Time Protocol (NTP). 20 It shall support the feature of sending an alarm in case - of storage disk failure. 21 Supports an alarm feature in case the hard disk - becomes full, in case data rewriting is not activated. 22 It shall support sending a status notification when - recording is turned On and Off. 23 It shall support sending a status notification of changes - in the recording schedule. 24 It shall support sending a warning notification in case - of the interruption or malfunction of the VSS camera. 25 It shall support sending a status notification of a user - login to the device with identification of the user. 26 It shall support sending a pulse signal that the device is - running. Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 10 of 140 27 Ability to recognize and write on Windows-compatible - storage media of various capacities. 28 Recording files shall be in standard formats that can be - viewed directly on the multimedia player software available in Windows operating system. 29 If the recording file formats are system-specific, - manufacturer-specific, encrypted, or non-standard, software must be provided to view them on Windows computers. B. Additional Specifications of Vehicles Recording Devices: SN Specifications Remarks 1 The ability to record, display, and extract - recordings simultaneously. 2 A display screen must be installed within the - driver's and assistant's line of sight. 3 The recording device must be stored in a clean, - secure location, protected from theft, vandalism, or tampering. 4 The device must be specifically designed for - vehicles. 5 It must be equipped with a solid-state drive - (SSD). 6 The system must be connected to the vehicle's - backup battery. 7 All system cables must be in secure cases. - C. Recording Duration and Quality: The recording must be kept for at least 31 days, at high quality, and at a frame rate of at least 10 frames per second. Third: Display devices SN Specifications Remarks All monitors shall be of high operational Monitors must be specifications to be suitable for continuous 1 designed for continuous operations without interruptions for a period not work 24/7 - 365 days. less than three years. The monitor’s resolution should not be less than 2 - Full HD 1080p. Monitors must be specific to surveillance and not 3 - television screens. At least two monitors must be available to each 4 security systems operator, the size of each shall - not be less than 21 inches. Wall monitors must be provided in the control The image size of each 5 rooms. camera should not be Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 11 of 140 less than 12 x 6.7 cm in the display monitor. The number of monitors required for displaying As described in the 6 cameras’ imaging shall be calculated with following paragraphs No. considering critical and normal cameras 7,8 This excludes establishments whose activities do not require an operations room and Monitors must be provided to display all cameras have less than 64 7 feeds. cameras or less than 4 recording devices, as one screen can be provided along with a KVM device. Monitors at Workstations • The monitor should not be less than 21 inches. • For each workstation, there must be at least 2 8 monitors. - The aspect ratio of the display on the monitor must be compatible with the aspect ratio of the capturing view of the camera (4:3, 16:9, 16:10). Critical cameras must be always displayed at the center of the wall display. These cameras include cameras at entrances, reception and assistance 9 desks, passenger drop-off areas, elevator lobbies - and stairwells on the main floors, the main lobby, and any other cameras deemed important by the security officer or as directed by SIRA. Standard cameras imaging must be displayed in ("set" is a matrix of the terminal areas of the full wall monitor in the different cameras form of sets of serial cameras, provided that the arranged to occupy the 10 total cycle time does not exceed 60 seconds, and display space on the the number of sets does not exceed 6 sets. monitor). Consequently, the serial cycle returns to the first set of cameras. Wall Monitors • The thickness of the outer frame of wall monitors shall not exceed 4 mm. 11 • Wall monitors shall allow the control of the - display modes (number of cameras to display). • Wall monitors shall allow the display of data and maps. Fourth: Connectors: SN Specifications Remarks Cables (copper clad Where twisted pairs are used, the type used aluminum) and (copper 1 must contain a minimum of high-quality copper clad iron) are not known as CAT 6. allowed. Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 12 of 140 There is no harm in using range extenders, 2 provided that the picture and signal quality are - not negatively affected. All system connections must be secured against tampering or accidental disconnection. This may 3 - be achieved by placing a lockable container in the system. All connections must be protected from 4 - tampering and unauthorized connections. High quality cables and connectors must be 5 - used. Appearance should be taken into consideration 6 when connecting and visible connections should - be avoided as much as possible. Exposed connections must be protected by plastic conduits for indoor use and metal 7 - conduits specially designed for outdoor use and manufactured specifically for wiring. Connections to all wire terminals must be 8 - numbered, identified, and labeled. All plans, drawings, equipment schedules, name 9 tables, and connection tables must match those - installed. The use of wireless networks for security 10 systems is prohibited unless approved by the - institution. International engineering and technical standards and requirements must be followed in 11 - extending, installing, numbering, and managing connections. Fifth: Network SN Specifications Remarks Any network infrastructure topology can be used Provided that all points 1 to suit the technical design and security system mentioned in the table requirements. are adhered to A separate, dedicated private network must be 2 - created and installed solely for security systems. The network must have redundancy and 3 sustainability characteristics, avoiding single, - irreplaceable major breakpoints. The backbone of the network must be equipped 4 with a secondary backup line that will replace it - in the event of a power outage or interruption. The network must be equipped with a network management system (NMS). This system must include all means of monitoring network 5 - operation, identifying outages, and automatically reporting them if the number of devices connected to the network exceeds 200 devices. Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 13 of 140 Consider dividing the network into segments and clusters if the number of devices connected to 6 - the network exceeds 200 to avoid forming a large, flat network. The network must be compatible with both 7 current standard IPv4 and IPv6 addressing and - management systems. An additional 20% of the total capacity must be 8 - calculated from the network system. Sixth: Energy sources SN Specifications Remarks Security systems must be powered by uninterruptible power supplies (UPS), capable of 1 - operating autonomously in the event of a power outage for at least 30 minutes. All recording devices in VSS systems must be 2 connected to a UPS. Connection to other VSS - systems is detailed in the relevant appendices. The recording devices and UPS must be integrated so that the UPS can automatically shut 3 down the recording devices when the remaining optional battery level in the UPS reaches 25% of the total charge. Seventh: Control and management SN Specifications Remarks VMS surveillance system management software must be provided for any VSS system connected 1 - to 64 or more cameras or 4 or more recording devices. Security features must be available to ensure 2 control and security through passwords and - multiple permissions. Control and monitoring stations (workstations) 3 must be ready, efficient, and dedicated to these - tasks only. When it is necessary to integrate different systems with security systems (such as integrating VSS systems with access control, 4 alarms, and building management systems), - PSIM security information management systems must be used after prior written approval from SIRA. Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 14 of 140 Chapter Two: Specifications of Access Control Systems First: General specifications SN Specifications Remarks To be compatible with all fire alarm systems 1 approved by the relevant authorities in the - emirate. 2 to be centralized - To be able to handle both analog and digital 3 - systems Second: Locking mechanisms SN Specifications Remarks 1 To be self-opening in case of emergency and it is - allowed the use of electromagnetic or electromechanical locks 2 They must be self-locking in case of emergency Any place where and only electromechanical if installed on the emergency self-locking following doors: locks are used and are • Financial safes and safes contain valuable likely to be operated by contents. people, the lock must • Safes containing hazardous materials. have a manual • Safes containing narcotics and restricted emergency release medications. feature, and this feature must be used only on the • Weapons and ammunition depots. secured side of the lock. • Detention and quarantine facilities. Third: Connectors SN Specifications Remarks 1 Wireless connections may not be used without - SIRA approval. 2 Copper-clad aluminum and copper-clad iron - cables are not permitted. 3 All internal connections of the system must be - secured against tampering or damage. 4 All electrical cables must be concealed or routed in - containment (plastic internally, galvanized metal externally) 5 All cables must be numbered, labeled, and - identified at both ends. All system diagrams, drawings, and tables must match the actual installed equipment. 6 All cables and connections must be installed - according to the standards relevant to the cable Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 15 of 140 type, in accordance with international specifications and standards. Fourth: Control Panel SN Specifications Remarks 1 All control panels must be equipped with a backup - battery to ensure continued operation during a main power outage for at least 4 hours. 2 Systems must be built based on communication - over the digital network. 3 Must be able to save all operations internally - when the connection to the central control system is lost, and to automatically complete the data update when the connection is restored. Fifth: Management and Control Software SN Specifications Remarks 1 must work on different platforms and operating - systems. 2 To retain login and logout details for all linked - devices for a period of no less than one year. 3 The enrolment station must be installed in a safe - location. 4 It should contain an interactive electronic map to - control the systems. 5 Complete software development kits (SDKs) must - be provided for all components of the access control systems, allowing for effective integration with other systems. Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 16 of 140 Chapter Three: Specifications for Alarm and Intruder Detection Systems. All system components must be third generation at a minimum. First: Sensors SN Specifications Remarks 1 The sensors field must cover protected areas so - that no area can be breached to stop or disable the security system. 2 Dual-technology motion detectors, such as - infrared and microwaves, should be used. 3 Vibration detection sensors must be used. - 4 Drilling detection sensors must be used. - 5 Glass break sensors must be used. - 6 Panic buttons and keys must be provided for - facility personnel to use in the event of an emergency, must be at a level that is easy to use and hidden. 7 Door Contact (For Normal and Fortified Doors) - Second: Visual and audible alarm and warning devices SN Specifications Remarks 1 The alarm (audio and visual) must be installed, - equipped with a loudspeaker, and a flashing light that attracts attention. 2 The device's ringing duration must be set for at - least 5 minutes or until the alarm is reset. 3 The alarm (audio and visual) must be installed at - a minimum of 110 dBA from a distance of 1 meter to be audible and its flashing visible from the outside. 4 The alarm (audio and visual) must be equipped - with a backup battery that can operate for 8 continuous hours. Third: Connectors SN Specifications Remarks 1 Connectors must be wired. Wireless connection of - sensors may only be used after obtaining prior written approval from SIRA. 2 Each sensor must be connected separately to the - control and alarm panel and to a single zone. Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 17 of 140 3 All system wires must be kept inside dedicated - conduits. 4 Alarms must not be installed outside the facility, - except for flashing lights and sirens. 5 The entire system must be equipped with a - backup power supply (UPS) that will operate it in the event of a power outage for at least 8 hours. 6 Copper-clad aluminum and copper-clad iron - cables are not permitted. 7 All cables must be numbered, labeled, and - identified at both ends of the cable. 8 All system diagrams, drawings, and schedules - must match the installed alarm devices. 9 All inter-connectors must be installed in - accordance with relevant standards, in accordance with international specifications and standards. Fourth: Control and alarm panel SN Specifications Remarks 1 The Alarm system control panel must be approved - by SIRA. 2 The control panel must be connected to the central - alarm station. 3 Each sensor must be programmed individually with - a separate zone and labeled to indicate its installation location. 4 To have communication devices approved by SIRA - 5 To be connected to the facility's lighting control - system so that it can turn on the lighting on site when an alarm is triggered. 6 The control panel must be installed in a secure, - hidden, and difficult-to-access location. 7 The keypad should be installed away from the - control panel and near the entry or exit door. 8 All parts of the alarm system must have a tamper - detection feature, which triggers an alarm signal when any part is opened, removed, disconnected, or the electrical power supply is interrupted. 9 The time allocated to disarm the Alarm system - must not exceed one minute. If a longer time is required, prior written approval from the organization must be obtained. 10 The number of incorrect attempts to disable the - Alarm system must not exceed three (3) consecutive attempts. Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 18 of 140 11 The control panel must be equipped with a backup - battery that can operate for 8 continuous hours. Fifth: General requirements for the system administrator SN Specifications Remarks 1 The facility manager must activate the alarm - system after the end of the working day or after evacuating the building. 2 The person in charge or assigned to the protected - facility must respond to an alarm or emergency. Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 19 of 140 Chapter Four: Locks Specifications Pry-resistant, puncture-resistant, and shear-resistant locks with high-quality security keys must be installed, based on Standard No. 2320:2012(E) Lock Standards, Fittings, Requirements, and Test Methods. First: General Specifications SN Specifications Remarks 1 The force resistance on the cylinder plug or - locking mechanism must not be less than 10 kN. 2 The torque resistance on the cylinder plug or - locking mechanism must be at least 20 Nm. 3 The lock pull resistance shall not be less than 70 - kN. 4 The lock's torsion resistance must not be less - than 1200 Nm. 5 The lock cutting resistance shall not be less than - 70 kN. 6 The lock body's impact resistance at low - temperatures must be at least: • 40°C • 6550 grams • 1400 mm 7 The drilling resistance of the lock body should not - be less than 4 minutes. 8 The cut resistance of the lock body shall not be - less than 4 minutes. Chapter Five: Specifications of Penetration-Resistant Glass First: General Specifications SN Specifications Remarks 1 Piercing-resistant glass or the use of piercing- - resistant films attached to a strong frame, on the facility's glass facades so that the glass resists penetration for at least 90 seconds. Chapter Six: HVM Barriers Specifications (External Perimeter Safety) These are used to control and block vehicle traffic to prevent intrusion attempts. First: Standards HVM must be appropriate for the location. Based on the nature of the location, the category is determined from the table in point 5 below, considering that they must be approved by SIRA in accordance with established procedures. Second: HVM Types Based on Shape (various shapes and styles are designed for this purpose): Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 20 of 140 SN Type Remarks 1 strong walls - 2 Bollards - 3 Road Blockers - 4 Planter boxes and containers - 5 Roadside assets and equipment - 6 Water pools and fountains - 7 Columns, whatever their use - 8 Landscape elements such as rocks, hills, dunes, - and bodies of water Third: Types of HVM from an operational perspective SN Type Remarks 1 Movable HVM, meaning they can be temporarily - deactivated (by moving, folding, or retracting them) to allow vehicles to pass through them, and then return to their original position. This is done manually or mechanically by authorized persons. 2 Fixed HVM, which are permanent, non-removable. - Fourth: Requirements SN Specifications Remarks 1 SIRA approval (prior to implementation) must be - obtained for the locations, design, and calculations of all types of HVM for each project. Fifth: Installation requirements SN Specifications Remarks 1 Light - • Vehicle weight: 1,500 kg • Vehicle type: Lightweight, two-wheel drive, with a rigid axle • Impact speed: 110 km/h • Impact angle: 90 degrees • Penetration distance: 0 meters 2 Medium - Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 21 of 140 • Vehicle weight: 7,500 kg • Vehicle type: Medium-sized four-wheel drive with rigid 2-axle axles • Impact speed: 80 km/h • Impact angle: 90 degrees • Penetration distance: 0 meters 3 Heavy - • Vehicle weight: 32,000 kg • Vehicle configuration: Heavy, 6x6, 4-wheel drive Rigid axle 4-link • Impact speed: 80 km/h • Impact angle: 90 degrees • Penetration distance: 0 meters Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 22 of 140 Part Two: Operational Controls Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 23 of 140 Chapter One: Operational Image Requirements First: Field of View 1. Inspection Field of View SN Description Remarks 1 The target image size must not be The camera should be positioned less than 400% of the viewing size of directly in front of the subject (the the display screen. In exceptional target) so that the center of the image cases and with the prior approval of is the spot between the eyes of a the institution, the density of image "standard target," which is an average elements may be used, such that it is height of 1.6 meters. The camera can not less than 1000 pixels per meter. be positioned at a horizontal angle of no more than 10 degrees to the right or left, and a vertical angle of no more than 10 degrees above or below the horizon. 2. Identification View SN Description Remarks 1 The face must be the most * The camera is mounted directly in prominent part of the image. The front of the person (target). The camera target image size must be at least can be mounted at a horizontal angle of 120% of the screen's viewing area. no more than 45 degrees to the right or In exceptional cases, with the prior left, and a vertical angle of no more approval from SIRA, an image than 20 degrees above or below the element density of at least 300 pixels horizon. per meter may be used. * Wide Dynamic Range (WDR) feature is required for cameras used for identification, regardless of their installation location. The WDR contrast ratio must be at least 110 dB. 3. Recognition View SN Description Remarks 1 The entire body and its immediate surroundings The camera is mounted should be the most prominent part of the image. to recognize a "standard Therefore, the target image size should not be less target" of 1.6 meters in than 50% of the viewing area of the display. In length from any angle to exceptional cases, and with prior approval from the right or left and a SIRA, an image element density of no less than vertical angle of no more 125 pixels per meter may be used. than 45 degrees above the horizon. Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 24 of 140 4. Observation View SN Description Remarks 1 The entire body and its immediate surroundings The camera is mounted must be the most prominent part of the image. to observe a "standard The target image must be at least 25% of the target" 1.6 meters tall viewing area on the display. In exceptional cases, from any angle, right or and with prior approval from SIRA, an image left, and at a vertical element density of at least 62.5 pixels per square angle no greater than 45 meter may be used. degrees above the horizon, unless otherwise specified. 5. Detection View SN Description Remarks 1 The entire body and the medium-sized The camera is mounted surroundings should be the most prominent part of to detect a "standard the image. The target image size should be at target" of 1.6 meters in least 10% of the viewing area of the display. In length from any angle to exceptional cases, and with prior approval from the right or left and a SIRA, the image element density may be no less vertical angle of no more than 30 pixels per meter. than 75 degrees above the horizon. 6. Monitoring View SN Description Remarks 1 The entire body and the wide, distant The camera is mounted surroundings must be the most prominent part of to monitor a "standard the image. The target image size must be at least target" measuring 1.6 5% of the viewing area of the display. In meters in height from any exceptional cases, and with prior approval from angle, right or left, and SIRA, an image element density of at least 12.5 any vertical angle above pixels per meter may be used. the horizon. 7. View of recognizing vehicle plates number (ANPR / NPR) SN Description Remarks 1 Electronic means: where a system approved by Refer to security SIRA is installed requirements for sectors 2 Visual means: These are used to provide a clear The camera can be image that enables the operator to accurately read installed to observe at an the vehicle registration plate. Therefore, the height angle of no more than 30 of the letters and numbers (target) displayed on degrees above the the screen must be full and not less than 20% of horizon and at a the viewing area of the display. In exceptional Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 25 of 140 cases, and with prior approval from the horizontal angle of no organization, a pixel density of no less than 400 more than 30 degrees. pixels per meter may be used. Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 26 of 140 Chapter Two: Remote Communication Requirements SN Description Remarks 1 Connecting the VSS system to the system integrity - monitoring service approved by SIRA (Installing a system for linking and following up the integrity of VSS) 2 Connecting the facility's alarm and intruder detection - systems to SIRA approved alarm systems monitoring system. 3 Connecting the electronic registration systems for - vehicle plate numbers to the system of linking and monitoring the electronic registration systems for vehicle plate numbers approved by SIRA Chapter Three: Management and Operation SN Description Remarks 1 An employee must be responsible for the facility's - security systems. They must be familiar with the use and operation of the systems and perform all operational tasks, such as copying, searching, and uploading clips, as well as efficiently handling system components. This employee is also responsible for ensuring the proper operation of the systems and immediately reporting any malfunctions, according to established procedures. 2 Standard warning signs and labels approved by SIRA - must be placed at all main entrances and inside the elevators, alerting the presence of surveillance systems. 3 A record must be provided for each copying - operation, containing all data related to the copying operation, who made it, where it was kept, or who received it, according to the approved form. 4 The time and date that all security systems operate - on must be real, correct, and consistent with reality, and all the different parts of the systems must be synchronized and update the time and date value automatically and in accordance with the related systems operating in SIRA. Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 27 of 140 Chapter Four: Security Lighting SN Description Remarks 1 Scenes within the range of surveillance cameras - must be fully lit and free of any dark areas. 2 Invisible security lighting (infrared) may be used - in secondary perimeter areas that are not primarily used or where visible light is insufficient for camera surveillance, provided that this lighting covers the range of vision of the surveillance cameras and that no infrared light is reflected in the camera. 3 The use of security lighting must not have any Such as the effect of negative impact on the safety of others. lighting on drivers' vision. Chapter Five: Image Acceptance SN Description Remarks 1 The image must be clear, and its contents can be - easily interpreted and read by the observer, and straight lines must be distinguishable without any image distortions. 2 The image should be stable and not shake even in - moderate wind conditions. 3 The camera's field of view must be accessible and - free of obstructions that obscure part of the image. An image will be considered unacceptable if the obstruction exceeds 5% of the total image area. The center of the image must be free of any obstructions, and the edges of the image must not exceed 5% of the total image area. Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 28 of 140 Chapter Six: The Sustainability of Security Systems SN Description Remarks 1 All digital recording devices must be installed in - secure, clean, and constantly monitored locations. Access to them must be restricted to authorized personnel only, and tampering with them must be prevented. The facility is fully responsible for maintaining a continuous, auditable log containing details of entry, exit, and activities related to the location where these devices are installed. The facility is also fully responsible for immediately notifying SIRA and maintenance company of any incident that prevents the security systems from functioning. 2 All security system connections must be - independent and dedicated solely to serving the security systems. These connections may not be part of an external wiring network and may not be connected to it unless the connection is for integration purposes. In that case, a firewall must be provided to secure it after obtaining prior written approval from SIRA. 3 All active components of the information network - serving security systems must be installed in secure and clean locations, and access to them must be restricted to authorized personnel only. Tampering with the equipment must be prohibited (whether primary or secondary switchboards or dedicated racks). The facility is fully responsible for maintaining a continuous and audited log containing details of entry, exit, and activities related to the location where these devices are installed. The facility is also fully responsible for immediately notifying the institution and maintenance company of any incident that prevents the security systems from functioning. 4 All wires and connections must be hidden and - within special wire containment means such as pipes, suspended conduits, buried receptacles, etc. Wires must not be exposed. 5 Electrical outlets that supply security systems and - their peripheral devices, such as cameras, controllers, etc., must be tamper-proof to avoid being intentionally turned off. 6 If there is a possibility that the building or facility - will be exposed to lightning, the security systems must be fully protected against lightning strikes and rebound charges from ground connections. Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 29 of 140 7 Security devices and equipment must be installed - in secure locations, away from tampering, vandalism, or accidents such as objects falling on them or colliding with them. 8 If installation conditions require that security - devices and equipment be installed within the reach of standard persons (i.e. persons with an average height of 1.6 meters and not equipped with additional equipment) of less than 2.5 meters, then these security devices and equipment must be equipped with tamper-proof and vandal-proof features and shock-resistant features of no less than IK10 according to the international standard classification. Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 30 of 140 Chapter Seven: Maintenance, Development and Modification of Security Systems SN Description Remarks 1 The facility is committed to entering an annual - maintenance contract with one of the companies registered with SIRA. The contract must include a preventive maintenance program with no less than four visits per year, along with the legal response and penalties for failure to comply. The facility is responsible for notifying SIRA if it fails to implement the terms of the maintenance contract. 2 The user, facility, and maintenance and installation The changes include all service provider are obliged to maintain a work and are not limited sustainable record and to notify SIRA when to the examples performing any work, procedure, or activity that mentioned. results in a total or partial change, even if minor: 1. Security system design. 2. Security system specifications or components. 3. Arrangement, definition, and programming of security system devices. 4. Maps of the area monitored by the security systems. 5. Lighting levels that affect the security systems. 6. The presence or addition of obstructions that impede the operation of the security systems. 7. Expanding or reducing the facility in terms of buildings and spaces or adding or merging buildings or commercial licenses. 8. Adding or removing entrances, exits, fences, or open areas to external public spaces. 9. Changes in activities or businesses. 10. The presence of adjacent projects or facilities that affect the security systems. 11. Any other action not mentioned here that affects the efficiency, comprehensiveness, or effectiveness of the security systems. 3 The entire technical maintenance crew must be - licensed by SIRA, and service providers must update their technical crew’s information directly and continuously with SIRA. Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 31 of 140 Chapter Eight: Prohibitions SN Description Remarks 1 It is prohibited to use cameras with pan and zoom - capabilities in private areas unless SIRA approval is obtained. 2 The use of hidden cameras is prohibited unless - SIRA approval is obtained. 3 It is prohibited to install external cameras on the - roof whose monitoring range exceeds the boundaries of the relevant facility unless SIRA approval is obtained. Chapter Nine: Exceptional Cases SN Description Remarks 1 If there are shared facilities or spaces in a facility that has - more than one activity, the maximum requirements must be applied to them. 2 Everything mentioned in the Preventive Systems Manual is - the minimum specifications and requirements that must be adhered to. Under no circumstances may equipment, installation, or implementation be carried out with specifications or requirements less than the minimum. It is not permissible to fail to adhere to any of its provisions except with official approval from SIRA. 3 SIRA may impose any additional security measures, security - service, study, analysis, evaluation, specifications, requirements, design, or amendment to the security, engineering, and architectural designs, according to the requirements of the security situation and as it deems appropriate. 4 The installation of security devices and equipment must not - cause the loss of security and safety requirements, such as fire-resistant doors or service outlets designed to prevent the spread of flames and fires and other specialized equipment, and its vehicles must not be obstructed. Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 32 of 140 Chapter Ten: Quality of Work and Installation SN Description Remarks 1 The appearance must not be distorted by untidy security - systems. Installation must be carried out within standard formal controls in terms of hiding or covering wires and using mounting bases specially manufactured for the purpose of installing security equipment. 2 All connections and wires must be numbered and marked - on both sides with standard markings and numbers and manufactured specifically for this purpose. 3 Safety measures must be observed, individuals and property - must not be harmed, and warning and guidance signs must be placed to avoid harming others. Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 33 of 140 Part Three: Security Requirements and Conditions Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 34 of 140 Chapter One: Security Conditions and Requirements for Luxury Hotels: Luxury hotels are commercial establishments that provide accommodation and hospitality services to visitors and travelers. First: Covered Activities Refer to the Commercial Establishments and Activities Annex Second: Security Requirements: A. Cameras must be installed to meet the following requirements: VSS Requirements SN Areas Field Of View Remarks 1 Entrances of the establishment Identification View - 2 cashier and reception desks Recognition View - 3 elevators lobbies and stairs Observation View - 4 Inside the elevators Observation View with an angle showing the floor number 5 emergency exit doors among Observation View - floors 6 Vehicle entrances and exits to Recognition View - the establishment 7 Safe and bag deposit room Recognition View - 8 entrances leading to the bars, Identification View - discos, nightclubs and the doors of ballrooms 9 Establishment corridors Detection View - 10 inside business centers Detection View - 11 loading and unloading areas Detection View - 12 Passenger drop-off and pick-up Monitoring View - area 13 External corridors leading to Detection View For units with an residential units external entrance 14 Corridors containing Monitoring View - restaurants or shops 15 Entrances from restaurants, Identification View - cafes, and shops that have an external entrance and are within the establishment's boundaries 16 parking lots pathways Detection View For establishment private or rented parking spaces 17 Main lobby area Detection View - 18 In the LPG storage area and Observation View - filling sites Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 35 of 140 19 Electrical room entrance Recognition View Main rooms only. If there is no covering for the corridors leading to the sub-electrical rooms, then the entrances to all electrical rooms must be covered. 20 Water tank room entrance Recognition View - 21 Entrances to fresh air handling Recognition View - units for the air conditioning system (FAHU) 22 Backup generator fuel tanks Detection View - 23 Vehicles Number-Plate Automatic At the Vehicles Recognition cameras shall be Number-Plate entrances and exits to installed Recognition system the establishment. (ANPR) approved If there is more than by SIRA one entrance, cameras should be installed at the following locations: o Vehicle entrances and exits to the establishment o Parking entrances and exits o Passenger drop-off areas entrance and exits o Loading and unloading areas B. The following security requirements must be provided: Other requirements SN Requirement Description Remarks 1 Room Entry An electronic room entry system with - System the following features: A. A lock registers at least 1,500 entry and exit movements. B. A record of movements is maintained for at least six months. 2 surveillance room Providing an independent, closed, and Maintain and unexposed surveillance room equipped operate the VSS with all means of communication with system in a guards, hotel officials, emergency, location with rescue, and ambulance services, and mobile network all means of assistance to manage or coverage. control the security system. Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 36 of 140 3 Security Guard Providing 24-hour security guards - according to the risk analysis report 4 Security Team Providing a security operations - Leader manager or security supervisor around the clock 5 Security manager A security manager must be available - on constant contact. 6 female guard Female security personnel must be - available when needed. 7 Security Systems Providing a security systems - Operator supervisor with a license approved by SIRA around the clock in the control room. 8 Installing system Installing system health monitoring - health monitoring service approved by SIRA service Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 37 of 140 Chapter Two: Security Conditions and Requirements for Tourist Hotels: Tourist hotels are commercial establishments that provide accommodation and hospitality services to visitors and travelers. First: Covered Activities Refer to the Commercial Establishments and Activities Annex Second: Security Requirements: A. Cameras must be installed to meet the following requirements: VSS Requirements SN Areas Field Of View Remarks 1 Entrances of the establishment Identification view - 2 cashier and reception desks Recognition View - 3 elevators lobbies and stairs Observation View - 4 Inside the elevators Observation View with an angle showing the floor number 5 emergency exit doors among Observation View - floors 6 Vehicle entrances and exits to Recognition View - the Establishment 7 safe and bag deposit rooms Recognition View - 8 entrances leading to the bars, Identification View - discos, nightclubs and the doors of ballrooms 9 Establishment corridors Detection View - 10 inside business centers Detection View - 11 loading and unloading areas Detection View - 12 Passenger drop-off and pick-up Monitoring View - area 13 External corridors leading to Detection View For units with an residential units external entrance 14 Corridors containing restaurants Monitoring View - or shops 15 Entrances from restaurants, Identification View - cafes, and shops that have an external entrance and are within the establishment's boundaries 16 parking lots pathways Detection View For establishment private or rented parking spaces 17 Main lobby area Detection View - 18 In the LPG storage area and Observation View - filling sites Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 38 of 140 19 Electrical room entrance Recognition View Main rooms only. If there is no covering for the corridors leading to the sub-electrical rooms, then the entrances to all electrical rooms must be covered. 20 Water tank room entrance Recognition View - 21 Entrances to fresh air handling Recognition View - units for the air conditioning system (FAHU) 22 Backup generator fuel tanks Detection View - 23 Vehicles Number-Plate Automatic Number- At the Vehicles Recognition cameras shall be Plate Recognition entrances and exits to installed system (ANPR) the establishment. approved by SIRA If there is more than one entrance, cameras should be installed at the following locations: o Vehicle entrances and exits to the establishment o Parking entrances and exits o Passenger drop-off areas entrances and exits o Loading and unloading areas B. The following security requirements must be provided: Other requirements SN Requirement Description Remarks 1 Room Entry An electronic room entry system with - System the following features: A. A lock registers at least 1,500 entry and exit movements. B. A record of movements is maintained for at least six months. 2 surveillance room Providing an independent, closed, Maintain and and unexposed surveillance room operate the VSS equipped with all means of system in a location communication with guards, hotel with mobile network officials, emergency, rescue, and coverage. ambulance services, and all means of Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 39 of 140 assistance to manage or control the security system. 3 Security Guard Providing 24-hour security guards - according to the risk analysis report 4 Security Team Providing a security operations - Leader manager or security supervisor around the clock 5 female guard Female security personnel must be - available when needed. 6 Installing system Installing system health monitoring - health monitoring service approved by SIRA service Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 40 of 140 Chapter Three: Security Conditions and Requirements for Shopping Malls: These are commercial establishments that combine a group of shops and stores in one location. First: Activities Covered Refer to the Commercial Establishments and Activities Annex Second: Specifications and Security Requirements A. Cameras must be installed to meet the following requirements: VSS requirements SN Areas Field Of View Remarks 1 Entrances of the Identification View - establishment 2 emergency exit doors Observation View - among floors 3 cashier and reception Recognition View - desks 4 elevators lobbies and Observation View - stairs 5 Inside the elevators Observation View with an angle showing the floor number, using a lens with a wide angle to cover all parts of the elevator. 6 Locations of ATMs, Recognition View So that the cash filling public phones, and angle is visible. public charging devices 7 Vehicle entrances and Recognition View - exits to the Establishment 8 Safe and baggage Recognition View - storage rooms, temporary storage service for purchases 9 Vehicles Number-Plate Automatic Number-Plate At the Vehicles entrances Recognition cameras Recognition system and exits to the shall be installed (ANPR) approved by establishment. SIRA If there is more than one entrance, cameras should be installed at the following locations: o Vehicle entrances and exits to the establishment o Parking entrances and exits Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 41 of 140 o Passenger drop-off areas entrances and exits o Loading and unloading areas Note: If the main entrance to all the mentioned areas is the same, only the main entrance should be covered. 10 loading and unloading Monitoring View - areas 11 Passenger drop-off and Monitoring View - pick-up area 12 Establishment corridors Detection View - 13 Seating and waiting Detection View - areas 14 parking lots pathways Detection View For establishment private or rented parking spaces 15 Main lobby area Detection View - 16 outdoor spaces, Monitoring View In addition to installing performance areas and PTZ cameras. crowd gathering areas 17 In the LPG storage area Detection View - and filling sites and gas cylinders storage areas 18 Electrical room entrance Recognition View - 19 Water tank room Recognition View - entrance 20 Entrances to fresh air Recognition View - handling units for the air conditioning system (FAHU) 21 Backup generator fuel Monitoring View - tanks B. The following security requirements must be provided: Other requirements SN Requirement Description Remarks Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 42 of 140 1 surveillance room Providing an independent, closed, and Maintain and unexposed surveillance room equipped operate the VSS with all means of communication with system in a guards, Mall officials, emergency, location with rescue, and ambulance services, and all mobile network means of assistance to manage or coverage. control the security system. 2 Security Guard Providing 24-hour security guards - according to the risk analysis report 3 Security Operations Providing a security operations - manager or security supervisor around the clock 4 Security Manager A security manager must always be - available on call. 5 female guard Female security personnel must be - available 6 Security Systems Providing a security systems supervisor - Operator with a license approved by SIRA around the clock in the control room. 7 Hostile Vehicle Hostile Vehicle Mitigation (HVM) - Mitigation (HVM) Stationary or mobile HVM that is approved shall be installed in front of the main gates and the areas where guests and visitors gather. 8 Permanent Security Permanent Security Guards shall be - Guards for gathering provided for areas or corridors where areas of gold and shops of gold, jewelry and precious precious goods goods are located. shops 9 Installing system Installing system health monitoring - health monitoring service approved by SIRA service Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 43 of 140 Chapter Four: Security Conditions and Requirements for Important Complexes: Any group of residential or office units, including buildings, towers, and villa complexes. First: Covered Activities Refer the Commercial Facilities and Activities Annex. Second: Specifications and Security Requirements for Multi-Story Residential Buildings: These are buildings used for residential purposes only. Cameras must be installed to meet the following requirements. VSS requirements SN Areas Field Of View Remarks 1 Entrances of the Identification View - establishment 2 reception desks Recognition View - 3 elevators lobbies and Observation View - stairs 4 Inside the elevators Observation View with an angle showing the floor number 5 Establishment corridors Detection View - 6 Health club entrances Recognition View - 7 swimming pools Monitoring View - 8 parking lots pathways Detection View - 9 Installing external Monitoring View Installing cameras on cameras around the the walls of the building's perimeter building A. Cameras must be installed in the complex’s gardens according to the following requirements: VSS requirements SN Areas Field Of View Remarks 1 Entrances of the establishment Identification View - 2 Vehicle entrances and exits Recognition View - 3 Establishment corridors Detection View - 4 Seating areas Detection View - 5 Outdoor areas, performance Monitoring View - venues, and visitor gatherings Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 44 of 140 B. Vehicles Number-Plate Recognition cameras: Vehicles Number-Plate Recognition cameras SN Areas Field Of View Remarks Vehicles Number- Vehicles Number-Plate At the entrances and exits of Plate Recognition Recognition view parking spaces, the parking cameras shall be spaces are to be used by 1 installed residents only and not by any residential units used as vacation homes. Note: If the parking spaces are used by visitors or the units are used for holiday homes, Automatic Number-Plate Recognition system (ANPR) approved by SIRA must be installed at the vehicle entrances and exits. C. The following security requirements must be provided: Other requirements SN Requirement Description Remarks security guard Providing a security -For buildings with fewer than 50 guard or watchman residential units, this is optional. 1 around the clock - For buildings with 50 or more residential units, this is mandatory. Provide a place A place for the security -If a security guard is used, a for the guard to guard or watchman to restroom must be provided for the work manage the work must guard. 2 be provided. -If a watchman is used, a suitable, fully equipped living room must be provided. Access control A system that controls - For buildings containing fewer system for both entry to the building than 50 residential units, it is residents and and prevents mandatory. - For buildings visitors unauthorized entry containing 50 residential units or 3 until permission is more, it is optional. granted by the concerned residents. 4 Installing system Installing system health - health monitoring monitoring service service approved by SIRA Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 45 of 140 Third: Specifications and security requirements for multi-story commercial buildings: A. Cameras must be installed to meet the following requirements: VSS requirements SN Areas Field Of View Remarks 1 Entrances of the Identification View - establishment 2 Entrances to the Identification View - establishment from shops 3 Main lobby areas Detection View - 4 elevators lobbies and Observation View - stairs 5 reception desks Recognition View - 6 Inside the elevators Observation View with an angle showing the floor number 7 emergency exit doors Observation View - among floors 8 Establishment corridors Detection View - 9 Health club entrances Recognition View - 10 swimming pools Monitoring View - 11 parking lots pathways Detection View - 12 Installing external Monitoring View Installing cameras on cameras around the the walls of the building's perimeter building B. Cameras must be installed in the complex’s gardens according to the following requirements: VSS requirements SN Areas Field Of View Remarks 1 Entrances of the establishment Identification View - 2 Vehicle entrances and exits Recognition View - 3 Establishment corridors Detection View - 4 Seating areas Detection View - 5 Outdoor areas, performance Monitoring View - venues, and visitor gatherings C. Vehicles Number-Plate Recognition cameras Vehicles Number-Plate Recognition cameras SN Areas Field Of View Remarks Vehicles Number- Automatic Number-Plate 1 Plate Recognition Recognition system - cameras shall be (ANPR) approved by installed SIRA Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 46 of 140 D. The following security requirements must be provided: Other requirements SN Requirement Description Remarks security guard Providing a security - 1 guard or watchman around the clock Provide a place A place for the security -If a security guard is used, a for the guard to guard or watchman to restroom must be provided for the work manage the work must guard. 2 be provided. -If a watchman is used, a suitable, fully equipped living room must be provided. 3 Installing system Installing system health - health monitoring monitoring service service approved by SIRA Fourth: Specifications and Security Requirements for Villa Complexes: Any group of residential villas. A. Cameras must be installed to meet the following requirements: VSS requirements SN Areas Field Of View Remarks 1 Entrances of the Identification View - establishment 2 elevators lobbies and Observation View In public areas stairs 3 Main lobby area Detection View - 4 reception desks Recognition View - 5 Inside the elevators Observation View In public areas 6 Internal street Detection View - intersections 7 Health club entrances Recognition View - 8 swimming pools Monitoring View - 9 The fence surrounding the It would be optional if site Monitoring View cameras were installed to cover internal streets. 10 internal streets It is optional if cameras Monitoring View are installed on the fence surrounding the site. 11 Vehicles Number-Plate Automatic Number-Plate At the entrances and Recognition cameras shall Recognition system exits of parking lots be installed (ANPR) approved by SIRA Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 47 of 140 12 parking lots pathways Detection View - B. Cameras must be installed in the complex’s gardens according to the following requirements: VSS requirements SN Areas Field Of View Remarks 1 Entrances of the establishment Identification View - 2 Vehicle entrances and exits Recognition View - 3 Establishment corridors Detection View - 4 Seating areas Detection View - 5 Outdoor areas, performance Monitoring View - venues, and visitor gatherings C. The following security requirements must be provided: Other requirements (villa complexes and building complexes or villa and building complex) SN Requirement Description Remarks 1 security guard Providing 24-hour security guards - 2 Provide a place A place for the security a washroom must be provided for for the guard to guard to manage the the guard. work work must be provided. 3 Installing system Installing system health - health monitoring monitoring service service approved by SIRA Fifth: Specifications and Security Requirements for Building Complexes: A complex containing a group of buildings. A. Cameras must be installed in accordance with the following requirements: VSS requirements SN Areas Field Of View Remarks 1 Entrances of the Identification View - establishment 2 elevators lobbies and Observation View In public areas stairs 3 Main lobby area Detection View - 4 reception desks Recognition View - 5 Inside the elevators Observation View In public areas 6 emergency exit doors Observation View In public areas among floors Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 48 of 140 7 Internal street Detection View - intersections 8 Health club entrances Recognition View - 9 swimming pools Monitoring View - 10 The fence surrounding the It would be optional if site Monitoring View cameras were installed to cover internal streets. 11 internal streets It is optional if cameras Monitoring View are installed on the fence surrounding the site. 12 Vehicles Number-Plate Automatic Number-Plate At the entrances and Recognition cameras shall Recognition system exits of parking lots be installed (ANPR) approved by SIRA 13 parking lots pathways Detection View - B. Cameras must be installed in the complex’s gardens according to the following requirements: VSS requirements SN Areas Field Of View Remarks 1 Entrances of the establishment Identification View - 2 Vehicle entrances and exits Recognition View - 3 Establishment corridors Detection View - 4 Seating areas Detection View - 5 Outdoor areas, performance Monitoring View - venues, and visitor gatherings C. The following security requirements must be provided: Other requirements (villa complexes and building complexes or villa and building complex) SN Requirement Description Remarks 1 security guard Providing 24-hour security guards - 2 Provide a place A place for the security a washroom must be provided for for the guard to guard to manage the the guard. work work must be provided. 3 Installing system Installing system health - health monitoring monitoring service service approved by SIRA Sixth: Specifications and Security Requirements for Villa and Building Complexes: These are complexes containing villas and residential buildings. Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 49 of 140 A. Cameras must be installed in accordance with the following requirements: VSS requirements SN Areas Field Of View Remarks 1 Entrances of the Identification View - establishment 2 elevators lobbies and Observation View In public areas stairs 3 Main lobby area Detection View - 4 reception desks Recognition View - 5 Inside the elevators Observation View In public areas 6 emergency exit doors Observation View In public areas among floors 7 Internal street Detection View - intersections 8 Health club entrances Recognition View - 9 swimming pools Monitoring View - 10 The fence surrounding the It would be optional if site Monitoring View cameras were installed to cover internal streets. 11 internal streets It is optional if cameras Monitoring View are installed on the fence surrounding the site. Vehicles Number-Plate Automatic Number-Plate At the entrances and 12 Recognition cameras shall Recognition system exits of parking lots be installed (ANPR) approved by SIRA 13 parking lots pathways Detection View - B. Cameras must be installed in the complex’s gardens according to the following requirements: VSS requirements SN Areas Field Of View Remarks 1 Entrances of the establishment Identification View - 2 Vehicle entrances and exits Recognition View - 3 Establishment corridors Detection View - 4 Seating areas Detection View - 5 Outdoor areas, performance Monitoring View - venues, and visitor gatherings C. The following security requirements must be provided: Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 50 of 140 Other requirements (villa complexes and building complexes or villa and building complex) SN Requirement Description Remarks 1 security guard Providing 24-hour security guards - 2 Provide a place A place for the security a washroom must be provided for for the guard to guard to manage the the guard. work work must be provided. 3 Installing system Installing system health - health monitoring monitoring service service approved by SIRA Seventh: Specifications and Security Requirements for Gated Building Complexes: A. Cameras must be installed to meet the following requirements: VSS requirements SN Areas Field Of View Remarks 1 Entrances of the Identification View - establishment 2 Main lobby area Detection View - 3 elevators lobbies and Observation View - stairs 4 reception desks Recognition View - 5 Inside the elevators Observation View with an angle showing the floor number 6 emergency exit doors Observation View - among floors 7 corridors leading to Detection View - residential units 8 Health club entrances Recognition View - 9 swimming pools Monitoring View - 10 Vehicles Number-Plate Number-Plate Recognition Installation is required Recognition cameras shall view at the entrances and be installed exits of parking areas if the establishment contains less than 50 residential units. 11 Installing external Monitoring View Installing cameras on cameras around the the walls of the building's perimeter building 12 Vehicles Number-Plate Automatic Number-Plate At the main entrances Recognition cameras shall Recognition system and exits leading to the be installed (ANPR) approved by SIRA gated complexes. 13 parking lots pathways Detection View - Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 51 of 140 14 Installing cameras around If there is a fence the fence surrounding the surrounding the site site (only if there are multiple uses for the site other than Detection View residential buildings), for example, there are multi-story buildings and a villa complex. B. Cameras must be installed in the complex’s gardens according to the following requirements: VSS requirements SN Areas Field Of View Remarks 1 Entrances of the establishment Identification View - 2 Vehicle entrances and exits Recognition View - 3 Establishment corridors Detection View - 4 Seating areas Detection View - 5 Outdoor areas, performance Monitoring View - venues, and visitor gatherings C. The following security requirements must be provided: Other requirements (villa complexes and building complexes or villa and building complex) SN Requirement Description Remarks 1 security guard Providing 24-hour security guards - 2 Provide a place A place for the security a washroom must be provided for for the guard to guard to manage the the guard. work work must be provided. 3 Installing system Installing system health - health monitoring monitoring service service approved by SIRA Eighth: Specifications and Security Requirements for Multi-Use Buildings: A. Cameras must be installed to meet the following requirements: VSS requirements SN Areas Field Of View Remarks 1 Entrances of the Identification View - establishment 2 Entrances of the Identification View - establishment from shops Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 52 of 140 3 Main lobby areas Detection View - 4 elevators lobbies and Observation View - stairs 5 reception desks Recognition View - 6 Inside the elevators Observation View with an angle showing the floor number 7 emergency exit doors Observation View - among floors 8 Establishment corridors Detection View - 9 Health club entrances Recognition View - 10 swimming pools Monitoring View - 11 parking lots pathways Detection View - 12 Installing external Monitoring View Installing cameras on cameras around the the walls of the building's perimeter building 13 Installing cameras around Detection View - the fence surrounding the site B. Cameras must be installed in the complex’s gardens according to the following requirements: VSS requirements SN Areas Field Of View Remarks 1 Entrances of the establishment Identification View - 2 Vehicle entrances and exits Recognition View - 3 Establishment corridors Detection View - 4 Seating areas Detection View - 5 Outdoor areas, performance Monitoring View - venues, and visitor gatherings C. Vehicles Number-Plate Recognition cameras Vehicles Number-Plate Recognition cameras SN Areas Field Of View Remarks Vehicles Number- Automatic Number-Plate Installation is required at the Plate Recognition Recognition system entrances and exits of parking 1 cameras shall be (ANPR) approved by spaces where non-residents are installed SIRA allowed to use the spaces. D. The following security requirements must be provided: Other requirements SN Requirement Description Remarks Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 53 of 140 1 security guard Providing a security -Mandatory for commercial guard or watchman buildings. around the clock -Optional for buildings with less than 50 residential units. -Mandatory for buildings with 50 or more residential units. 2 Provide a place A place for the security -If a security guard is used, a for the guard to guard or watchman to restroom must be provided for the work manage the work must guard. be provided. -If a watchman is used, a fully equipped and suitable living room must be provided. 3 Installing system Installing system health - health monitoring monitoring service service approved by SIRA Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 54 of 140 Chapter Five: Security Requirements for Labor Accommodations: These are designated accommodations for workers, typically used to provide temporary or permanent housing for them. First: Covered Activities Refer to the Commercial Establishments and Activities Annex Second: Specifications and Security Requirements A. Cameras must be installed to meet the following requirements: VSS requirements SN Areas Field Of View Remarks 1 Entrances of the establishment Identification - View 2 emergency exit doors among Observation - floors View 3 Dining and sitting rooms and Common areas include, common areas for residents Monitoring View for example, washing areas. 4 elevators lobbies and stairs Observation - View 5 With an angle showing the floor number, a wide- Inside the elevators Observation angle lens shall be used View to cover all parts of the elevator. 6 Reception areas Recognition - View 7 Establishment corridors Detection View - 8 Health club entrances Observation - View 9 swimming pools Monitoring View - 10 Installing cameras on vehicle Vehicles - entrances Number-Plate Recognition view 11 Vehicle parking pathways Detection View - 12 The area surrounding the labor Detection View On the wall of the accommodations building 13 outdoor areas Detection View - Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 55 of 140 B. The following security requirements must be provided: Other requirements SN Requirement Description Remarks 1 Security guard Providing 24-hour security guards - 2 Installing system Installing system health monitoring - health monitoring service approved by SIRA service Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 56 of 140 Chapter Six: Security Conditions and Requirements for Cinemas and Theaters: These are entertainment venues used to show films, plays, and various artistic works. First: Covered Activities Refer to the Commercial Facilities and Activities Annex Second: Security Specifications and Requirements A. Cameras must be installed to meet the following requirements: VSS requirements SN Areas Field Of View Remarks 1 Entrances of the Identification View - establishment 2 emergency exit doors Observation View - among floors 3 Main lobby area Detection View - 4 cashier and reception Recognition View - desks 5 Inside the safe deposit Recognition View - boxes rooms 6 elevators lobbies and stairs Observation View - 7 With an angle showing the floor number, a Inside the elevators Observation View wide-angle lens shall be used to cover all parts of the elevator. 8 ATM locations Recognition View - 9 Establishment corridors Detection View - 10 Seating and display areas Detection View - 11 Vehicle entrances to the Recognition View - establishment 12 loading and unloading Monitoring View - areas 13 Passenger drop-off and Monitoring View - pick-up area 14 parking lots pathways Detection View - 15 Gas cylinder storage area Observation View - 16 Vehicles Number-Plate Automatic Number-Plate - Recognition cameras shall Recognition system be installed (ANPR) approved by SIRA Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 57 of 140 B. The following security requirements must be provided: Other requirements SN Requirement Description Remarks VSS control room Providing a surveillance control - 1 room that is independent, closed, and non-exposed from the outside. 2 security guard Providing security guards - 3 female guard Female security guard must be - present. 4 Installing system health Installing system health monitoring - monitoring service service approved by SIRA Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 58 of 140 Chapter Seven: Security Conditions and Requirements for Amusement Parks: These parks are specifically designed to provide entertainment and enjoyment for visitors. These parks contain a variety of activities, games, and facilities that attract families and individuals. First: Covered Activities Refer to the Commercial Facilities and Activities Annex Second: Specifications and Security Requirements A. Cameras must be installed to meet the following requirements: VSS requirements SN Areas Field Of View Remarks 1 Entrances of the Identification View - establishment 2 cashier and reception Recognition View - desks 3 elevators lobbies and Observation View - stairs 4 Inside the elevators Observation View With an angle showing the floor number, a wide-angle lens shall be used to cover all parts of the elevator. 5 ATM locations Recognition View - 6 Vehicle entrances Recognition View - 7 loading and unloading Monitoring View - areas 8 Passenger drop-off and Monitoring View - pick-up area 9 Establishment corridors Detection View - 10 Seating areas Detection View - 11 parking lots pathways Detection View - 12 Outdoor spaces, Monitoring View - performance venues, and visitor gatherings 13 In the LPG storage Detection View - area and filling sites 14 Electrical room Recognition View - entrance 15 Backup generator fuel Detection View - tanks 16 Vehicles Number-Plate Automatic Number-Plate Private or rented Recognition cameras Recognition system (ANPR) parking shall be installed approved by SIRA Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 59 of 140 17 Chemical storage Observation View In water parks rooms 18 Pools Water treatment Observation View In water parks rooms Note: If the facility has an open nature and does not have defined entrances or lobby areas, the Pixel Per Meter (PPM) feature can be used after obtaining prior approval from SIRA. B. The following security requirements must be provided: Other requirements SN Requirement Description Remarks 1 Security Guard Providing 24-hour security guards - 2 Security manager A security manager must always be - available on call. 3 female guard Female guard must be available - 4 Operations room A dedicated operations room must be - provided to control and manage the cameras. It must be equipped with all means of communication with guards, officials at the amusement parks, emergency, rescue, and ambulance services, and all means of assistance to manage or control the security system. 5 Security Systems Providing a licensed security systems - operator operator approved by SIRA around the clock in the control room. 6 Hostile Vehicle Stationary or mobile HVM that are - Mitigation (HVM) approved shall be installed in front of the main gates and the areas where guests and visitors gather 7 Installing a secure - Chemical storage rooms - lock approved by - Aquarium water treatment rooms SIRA 8 Installing system Installing system health monitoring - health monitoring service approved by SIRA service Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 60 of 140 Chapter Eight: Security Conditions and Requirements for Educational Facilities: Educational facilities include a wide range of institutions that provide educational and training services to students and learners of various ages and educational levels. First: Covered Activities Refer to the Annex on Commercial Facilities and Activities Second: Specifications and Security Requirements for Nurseries and Kindergartens A. Cameras must be installed to meet the following requirements: VSS requirements (nurseries and kindergartens) SN Areas Field Of View Remarks 1 Entrances of the Identification View - establishment 2 emergency exit doors Observation View - among floors 3 Establishment Detection View - corridors 4 elevators lobbies and Observation View - stairs 5 Inside the elevators Observation View With an angle showing the floor number, a wide-angle lens shall be used to cover all parts of the elevator. 6 Waiting halls Detection View - 7 Stairs leading to the Detection View - roof 8 cashier and reception Recognition View - desks 9 Inside classrooms Detection View - 10 Outdoor play areas or Detection View - event areas at the establishment 11 Washrooms Recognition View - entrances 12 Vehicles Number- Automatic Number-Plate - Plate Recognition Recognition system cameras shall be (ANPR) approved by SIRA installed 13 The external Detection View - perimeter of the establishment Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 61 of 140 B. The following security requirements must be provided: Other requirements SN Requirement Description Remarks 1 Security Guard Providing 24-hour security guards - 2 Installing system Installing system health monitoring - health monitoring service approved by SIRA service Third: Specifications and Security Requirements for Schools A. Cameras must be installed in accordance with the following requirements: VSS requirements (schools) SN Areas Field Of View Remarks 1 Entrances of the Identification View - establishment 2 emergency exit doors Observation View - among floors 3 Establishment Detection View - corridors 4 elevators lobbies and Observation View - stairs 5 Inside the elevators Observation View With an angle showing the floor number, a wide-angle lens shall be used to cover all parts of the elevator. 6 Waiting halls Detection View - 7 Stairs leading to the Detection View - roof 8 cashier and reception Recognition View - desks 9 Inside classrooms Detection View - 10 Laboratories Detection View - 11 Outdoor play areas or Monitoring View - event areas at the establishment, for example Sports fields, swimming pools, and playgrounds 12 washrooms entrances Recognition View - 13 Inside the Detection View - establishment's clinic room Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 62 of 140 14 Inside rooms of Detection View - people with disabilities 15 Inside the large Detection View - exhibition halls 16 The outer wall of the Detection View - establishment 17 Inside the storage Detection View The Establishment file and rooms equipment storage rooms, if any 18 Safes for cash and Recognition View - important documents 19 Men's changing Recognition View - rooms entrances 20 Vehicles Number- Automatic Number-Plate - Plate Recognition Recognition system cameras shall be (ANPR) approved by SIRA installed 21 The external Detection View - perimeter of the establishment B. The following security requirements must be provided: Other requirements SN Requirement Description Remarks 1 Security Guard Providing 24-hour security guards - 2 Installing system Installing system health monitoring - health monitoring service approved by SIRA service Fourth: Security Specifications and Requirements for Universities and Colleges A. Cameras must be installed in accordance with the following requirements: VSS requirements (universities and colleges) SN Areas Field Of View Remarks 1 Entrances of the Identification View - establishment 2 emergency exit doors Observation View - among floors 3 Establishment Detection View - corridors 4 elevators lobbies and Observation View - stairs Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 63 of 140 5 Inside the elevators Observation View With an angle showing the floor number, a wide-angle lens shall be used to cover all parts of the elevator. 6 Waiting halls Detection View - 7 Staircase areas Detection View - leading to the roof 8 cashier and reception Recognition View - desks 9 Inside classrooms Detection View - 10 Laboratories Detection View - 11 Outdoor play areas or Monitoring View - event areas at the establishment, for example Sports fields, swimming pools, and playgrounds 12 Washrooms Recognition View - entrances 13 Inside the Detection View - establishment's clinic room 14 Inside rooms of Detection View - people with disabilities 15 Inside the large Detection View - exhibition halls 16 The outer wall of the Detection View - establishment 17 Inside the storage Detection View The Establishment file and rooms equipment storage rooms 18 Safes for cash and Recognition View - important documents 19 Men's changing Recognition View - rooms entrances 20 Vehicles Number- Automatic Number-Plate - Plate Recognition Recognition system cameras shall be (ANPR) approved by SIRA installed 21 The external Detection View - perimeter of the establishment Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 64 of 140 B. The following security requirements must be provided: Other requirements SN Requirement Description Remarks 1 Security Guard Providing 24-hour security guards - 2 Installing system Installing system health monitoring - health monitoring service approved by SIRA service Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 65 of 140 Chapter Nine: Security Requirements for Healthcare Facilities: Facilities that provide healthcare services to patients and communities, including a wide range of medical and healthcare services. First: Covered Activities Refer to the Facilities and Commercial Activities Annex Second: Specifications and Security Requirements A. Cameras must be installed to meet the following requirements: VSS requirements SN Areas Field Of View Remarks 1 Entrances of the establishment Identification view - 2 emergency exit doors among Observation View - floors 3 Main lobby Detection View - 4 Establishment corridors Detection View - 5 elevators lobbies and stairs Observation View - 6 With an angle showing the floor number, a wide- Inside the elevators Observation View angle lens shall be used to cover all parts of the elevator. 7 cashier and reception desks Recognition View - 8 Washroom Main entrances Detection View - 9 Loading and unloading areas Monitoring View - 10 Laboratories room entrances Recognition View - 11 Inside blood units storage rooms Detection View - 12 Pharmacy and medicine Detection View - dispensing area 13 Medicine shelves in the pharmacy Detection View - 14 Operation room entrances Recognition View - 15 Anesthesia room entrances Recognition View - 16 Intensive care unit entrances Recognition View - 17 Seating and waiting areas Detection View - 18 Inside the nursery rooms for Detection View - infants 19 Inside the storage rooms Detection View - 20 Inside medicine storage rooms Detection View - 21 Nursing centers and stations in Detection View - the establishment Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 66 of 140 22 Entrances to electrical and Recognition View - mechanical rooms, and medical gas storage areas 23 Sterile Supply Unit Entrances A room used to Detection View sterilize medical equipment in hospitals 24 Vehicles Number-Plate Automatic Number- - Recognition cameras shall be Plate Recognition installed system (ANPR) approved by SIRA 25 Passenger drop-off and pick-up Monitoring View - area 26 parking lots pathways Detection View - 27 The external perimeter of the Detection View - establishment 28 Helipads Detection View - 29 Patient drop-off areas from the Detection View - ambulance 30 Ambulance parking Detection View - B. Provide an access control system according to the following requirements: Access control system SN Requirement Areas Remarks 1 Provide access control system Entrances for staff and - doctors 2 Provide access control system Rooms for storing - medicines and various medical equipment 3 Provide access control system The intensive care unit - includes entrances, exits, and internal rooms. 4 Provide access control system Electrical, air conditioning - and mechanical rooms 5 Provide access control system Data storing centers and - server rooms 6 Provide access control system The hospital's quarantine - section, including entrances, exits, and internal rooms. 7 Provide access control system The Pharmacy - Department includes entrances and exits for employees, doctors, and pharmacists. Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 67 of 140 8 Provide access control system Radiology Department, - including entrances to imaging rooms 9 Provide access control system File rooms for storing files - and documents for patients, staff, and doctors 10 Provide access control system Newborns and maternity - departments, including entrances, exits, and internal rooms 11 Provide access control system Internal meeting rooms - for staff and doctors 12 Provide access control system Storage rooms of Various - medical gasses C. The following security requirements must be provided: Other requirements SN Requirement Description Remarks 1 Security Guard Providing 24-hour security guards - 2 Installing system Installing system health monitoring - health monitoring service approved by SIRA service Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 68 of 140 Chapter Ten: Security Requirements for Non-Muslim Places of Worship: These are places licensed for the performance of worship and religious rites for non- Muslim religions and sects. First: Covered Activities Refer to the Commercial Facilities and Activities Annex Second: Specifications and Security Requirements A. Cameras must be installed in accordance with the following requirements: VSS requirements SN Areas Field Of View Remarks 1 Entrances of the Identification view - establishment 2 Areas of worship Monitoring View - 3 reception desks Recognition View - 4 The area surrounding the Detection View All cameras are place of worship equipped with infrared features. 5 Appendices of places of Detection View All cameras are worship equipped with infrared features. 6 Vehicle parking Detection View - 7 elevators lobbies and Observation View - stairs 8 Vehicles Number-Plate Vehicles Number-Plate - Recognition cameras shall Recognition system be installed B. The following security requirements must be provided: Other requirements SN Requirement Description Remarks 1 Security Guard Providing 24-hour security guards - according to the risk analysis report 2 Installing system Installing system health monitoring - health monitoring service approved by SIRA service Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 69 of 140 Chapter Eleven: Security Requirements for the Manufacture and Sale of Precious Metals and Gemstones: The manufacture and trade of precious metals and gemstones includes all operations related to the extraction, manufacturing, and trade of precious metals such as gold, silver, and gemstones. First: Covered Activities Refer to the Annex on Establishments and Commercial Activities Second: Specifications and Security Requirements for Commercial Stores: These are stores that sell and trade gold, manufactured and unmanufactured jewelry, and gemstones, retail or wholesale. A. Cameras must be installed in accordance with the following requirements: VSS requirements SN Areas Field Of View Remarks 1 Entrances of the Identification View - establishment 2 Display and inspection tables Observation View - 3 cashier and reception desks Recognition View - 4 The safe Recognition View - 5 Display tables and cases that - extend beyond the Recognition View establishment's boundaries or displayed at another location. 6 The camera's viewing angle must be no less than 110 degrees. This requirement is exempted inside malls and External area of the Monitoring View buildings. establishment 7 Internal area of the Monitoring View - establishment Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 70 of 140 B. Alarm system must be provided according to the following requirements: Alarm system SN Requirement Details Remarks 1 Protected areas, Covering all areas with motion sensors is - offices, and comprehensive and not limited to administration protected areas, offices, and areas directly administrative areas directly connected to connected to the the shop, so that no area can be shop penetrated to stop or disable the security system. 2 glass facades All glass facades of the facility must be - secured with glass break sensors or motion detectors; these facades must not be openable in any way. 3 Entrances and Main and secondary entrances and - exits emergency exits, if any, must be equipped with magnetic keys or motion detectors. 4 The safe The safe must be equipped with a - vibration sensor or motion detector. 5 Panic button The cashier, seller, and manager must be - provided with a panic button for use in case of an emergency. It must be located at a level that is easy to use and not visible. 6 Alarm system Alarm system components must be - certified by SIRA C. The following security requirements must be provided: Other requirements SN Requirement Description Remarks 1 solid metal grille A fixed iron grille must be installed on all external openings that are not in the display area, such as windows in - service rooms, bathrooms, and ventilation rooms. 2 locks SIRA approved locks must be This installed. requirement is exempted if an automatic iron shutter that operates with a control button is provided. 3 uninterruptible power All cameras and recording devices - supply must be connected to an Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 71 of 140 uninterruptible power supply (UPS) for 30 minutes. 4 Installing system health Installing system health monitoring - monitoring service service approved by SIRA D. The following requirements must be provided to secure glass facades for shops and doors by one of the following means: Securing glass facades for shops SN Requirement Description Remarks iron curtains Iron curtains must be installed and - 1 closed after official working hours. piercing -resistant glass The facility must use piercing- resistant glass or piercing-resistant 2 films attached to the outer frame of - the glass facades. Third: Specifications and Security Requirements for Gold Offices These are institutions or companies that provide various services related to the trade in precious metals and gemstones. These services include the repurchase and sale of precious metals, whether in the form of jewelry, bullion, gold coins, or scrap gold, provided that no exhibits or collectibles are kept in the office and that its work is limited to office work. A. Cameras must be installed to meet the following requirements: VSS requirements SN Areas Field Of View Remarks 1 Entrances of the Identification View - establishment 2 Internal area of the Monitoring View - establishment B. The following security requirements must be provided: Other requirements SN Requirement Description Remarks 1 uninterruptible power All cameras and recording devices - supply must be connected to an uninterruptible power supply (UPS) for 30 minutes. 2 Installing system health Installing system health monitoring - monitoring service service approved by SIRA Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 72 of 140 Note: If precious metals or gemstones are kept or displayed at a gold office, then gold shops requirements must be applied. Fourth: Specifications and Security Requirements for Flexible or Virtual Offices This is the common name for a shared office used by a group of institutions and companies for a single location in a facility, or virtual offices that are not located in a specific facility but rather exist on the virtual world or on the internet: A. Conditions: - No exhibits may be kept. - No safe may be used for storing valuables. - Valuables may not be stored. B. Security Requirements: - There are no security requirements if the above requirements are adhered to. Note: 1. It is strictly prohibited for these activities to display or store precious metals and gemstones in flexible offices. 2. If the offices are separated by any type of partition, the above office requirements apply. 3. If precious metals or gemstones are stored or displayed in the flexible office, the requirements for commercial stores apply. Fifth: Specifications and Security Requirements for Business Centers This is a physical location that provides temporary office solutions for all types of entrepreneurs and institutions. These spaces offer private or shared office solutions with reception, email, and internet services. A. Requirements: - No exhibits may be kept. - No safe may be used for storing valuables. - Valuables may not be stored. B. Security Requirements: - No security requirements apply if the above requirements are met. Note: 1. The display or storage of precious metals and gemstones is strictly prohibited for these activities. 2. If the offices are separated by any type of partition, the above office requirements apply. 3. If precious metals or gemstones are kept or displayed in business centers, the requirements for commercial stores apply. Sixth: Specifications and Security Requirements for Jewelry and Precious Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 73 of 140 Goods Exhibitions Jewelry and precious goods exhibitions are places where fine jewelry and precious goods, such as gemstones, gold and silver jewelry, and precious works of art, are displayed. These exhibitions are typically held to display and sell fine art and jewelry to the public and investors and include all temporary exhibitions. A. Cameras must be installed to meet the following requirements: VSS requirements SN Areas Field Of View Remarks 1 Entrances of the establishment Identification View - 2 The safe Recognition View - 3 display tables Recognition View - 4 Exhibition area Monitoring View - 5 Recording retention period Keep recording for one - month after the exhibition ends. B. The following security requirements must be provided: Other requirements SN Requirement Description Remarks 1 security guard Providing security guards according to - the risk analysis report 2 defining the safe area A specific area where the cabinet(s) - will be placed by all exhibition participants must be designated by. C. Alarm system must be provided according to the following requirements: Alarm system SN Requirement Details Remarks 1 The safe The safe must be equipped - with a vibration sensor or motion detector. 2 Panic button The guard must be provided - with a panic button for use in the event of an emergency. It must be located at a level that is easy to use and not visible. 3 Alarm system Alarm system components - must be certified by SIRA. Seventh: Specifications and Security Requirements for Kiosks These are open-air shops in the aisles for the sale and trade of gold, manufactured and unmanufactured jewelry, and precious stones. Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 74 of 140 A. Cameras must be installed to meet the following requirements: VSS requirements SN Areas Field Of View Remarks 1 Display and sales tables Observation View - 2 Cash Registers Recognition View - B. Alarm system must be provided according to the following requirements: Alarm system SN Requirement Details Remarks 1 The safe The safe must be equipped with a - vibration sensor or motion detector. 2 Panic button The cashier, seller, and manager must be - provided with a panic button for use in case of an emergency. It must be located at a level that is easy to use and not visible. 3 Alarm Alarm system components must be - system approved by SIRA. C. The following security requirements must be provided: Other requirements SN Requirement Description Remarks 1 Installing system health Installing system health monitoring - monitoring service service approved by SIRA Eighth: Specifications and security requirements for display windows and platforms outside the store: A. The following security requirements must be provided: Security Requirements SN Requirement Description Remarks 1 piercing -resistant glass The facility must use piercing- - resistant glass or piercing-resistant films attached to the outer frame of the glass facades. 2 Locks SIRA approved locks must be - installed. 3 Alarm system Local alarm system linked to sirens - Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 75 of 140 Chapter Twelve: Security Requirements for Financial and Monetary Institutions: Financial and monetary institutions include a wide range of entities that provide diverse financial services to individuals and businesses. First: Activities Covered Refer to the Annex on Establishments and Commercial Activities Second: Specifications and Security Requirements for Financial and Monetary Institutions A. Cameras must be installed to meet the following requirements: VSS requirements SN Areas Field Of View Remarks 1 Entrances of the Identification View - establishment 2 cashier and reception Recognition View - desks 3 safes Recognition View - 4 Main lobby area Monitoring View - 5 Inside ATMs To show the image of the ATM - user 6 ATMs at the Observation View So that the cash establishment filling angle is visible 7 Safe rooms Recognition View - 8 External area of the Monitoring View The camera's establishment viewing angle should not be less than 110 horizontal degrees. 9 Recording retention Not less than 31 days for on-site - period cameras and not less than 75 days for ATM cameras. B. Alarm system must be provided according to the following requirements: Alarm and intruder detection system SN Requirement Details Remarks 1 Protected Areas The sensor range must cover - Protected Areas so that there is no area that can be penetrated to stop or disable the security system. 2 glass facades All glass facades of the facility must - be secured with glass breakage sensors or motion detection sensors. Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 76 of 140 3 Entrances and exits Main and secondary entrances and - emergency exits, if any, must be equipped with magnetic keys or motion detectors. 4 The safe The safe must be equipped with a - vibration sensor or motion detector. 5 Panic button The cashier, seller, and manager must - be provided with a panic button for use in case of an emergency. It must be located at a level that is easy to use and not visible. 6 Alarm system Alarm system components must be - approved by SIRA C. The following security requirements must be provided: Other requirements SN Requirement Description Remarks 1 Security Guard Providing Security Guard during - official working hours 2 Iron Grille A fixed iron grille must be installed on - all external openings that are not located in the trading area, such as windows in service rooms, bathrooms, and ventilation rooms. 3 iron curtains Iron curtains must be installed and It will be must be closed after official working cancelled if hours. piercing- resistant glass is provided. 4 piercing-resistant Piercing-resistant glass or piercing- It will be glass resistant films attached to the outer cancelled if iron frame must be used on glass facades curtains are for the facility, such that it prevents provided. glass penetration for a period of not less than 90 seconds. 5 uninterruptible power All cameras and recording devices - supply must be connected to an uninterruptible power supply (UPS) for 30 minutes. 6 Locks SIRA approved locks must be The above installed. requirement is excluded if the customer provides an automatic iron shutter that operates with a control button. Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 77 of 140 7 Access control system An access control system must be - installed at the main doors leading to the trading areas. 8 Installing system Installing system health monitoring - health monitoring service approved by SIRA service Third: Security Requirements for Electronic Banking Services Electronic banking services are banking services provided by banks and financial institutions via the internet and mobile applications. A. Cameras must be installed to meet the following requirements: VSS requirements SN Areas Field Of View Remarks 1 Entrances of the Identification View - establishment 2 cashier and reception desks Recognition View - 3 Cash Registers Recognition View - 4 The safe Recognition View - 5 Lobby area Monitoring View - 6 ATMs Recognition View So that the cash filling angle is visible B. The following security requirements must be provided: Other requirements SN Requirement Description Remarks 1 uninterruptible power All cameras and recording devices - supply must be connected to an uninterruptible power supply UPS for 30 minutes. 2 Installing system health Installing system health monitoring - monitoring service service approved by SIRA Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 78 of 140 C. Alarm system must be provided according to the following requirements: Alarm and intruder detection system (if a safe is available on site) SN Requirement Details Remarks Protected Areas, offices and All areas must be covered - administration areas directly with motion sensors, connected to the store including but not limited to protected areas, offices, and 1 administrative areas directly connected to the store, so that no area can be penetrated to stop or disable the security system. All glass facades of the - 2 glass facades facility must be secured with glass break sensors. Main and secondary - 3 Entrances and exits entrances and emergency exits, if any, must be equipped with magnetic keys. The safe The safe must be equipped - 4 with a vibration sensor or motion detector. The cashier, seller, and - 5 Panic button manager must be provided with a panic button for use in the event of an emergency. It must be located at a level that is easy to use and not visible. Alarm system Alarm system components - 6 must be approved by SIRA. D. The following security requirements must be provided: Other requirements (if a safe is available on site) SN Requirement Description Remarks 1 Iron Grille A fixed iron grille must be installed on all - external openings that are not located in the trading area, such as windows in service rooms, bathrooms, and ventilation rooms. Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 79 of 140 2 iron curtains Iron curtains must be installed that close If the bank is in after the end of official working hours, or a mall, iron piercing-resistant glass or piercing-resistant curtains are not films must be used, fixed to the outer required. Only frame, on the glass facades of the facility, piercing- such that they prevent glass penetration for resistant glass a period of no less than 1.5 minutes. or films are sufficient. 3 locks SIRA approved locks must be installed. The above requirement is excluded if the customer provides an automatic iron shutter that operates with a control button. Fourth: Security Requirements for Hawala Dar Hawala Dar is a money transfer business that also carries out a related commercial activity. A. Cameras must be installed to meet the following requirements: VSS requirements SN Areas Field Of View Remarks 1 Entrances of the Identification View - establishment 2 cashier and reception desks Recognition View - 3 safes Recognition View - 4 Lobby area Observation View - 5 Safe deposit rooms Recognition View - 6 External area of the Monitoring View The camera establishment viewing angle must be at least 110 degrees. Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 80 of 140 B. Alarm system must be provided according to the following requirements: Alarm and intruder detection system SN Requirement Details Remarks Protected Areas, offices All areas must be covered with - and administration motion sensors, including but not areas directly limited to protected areas, offices, 1 connected to the shop and administrative areas directly connected to the shop, so that no area can be penetrated to stop or disable the security system. All glass facades of the facility must - 2 glass facades be secured with glass breakage sensors or motion detection sensors. Main and secondary entrances and - 3 Entrances and exits emergency exits, if any, must be equipped with magnetic keys. The safe The safe must be equipped with a - 4 vibration sensor or motion detector. The cashier, seller, and manager - must be provided with a panic 5 Panic button button for use in case of an emergency. It must be located at a level that is easy to use and not visible. Alarm system Alarm system components must be - 6 approved by SIRA. C. The following security requirements must be provided: Other requirements SN Requirement Description Remarks 1 Providing security Security must be provided - guards during official working hours. 2 Iron Grille A fixed iron grille must be - installed on all external openings that are not located in the trading area, such as windows in service rooms, bathrooms, and ventilation rooms. 3 Iron curtains must be installed Or piercing-resistant glass and closed after official working or piercing-resistant films hours. attached to the outer frame must be used on the facility's glass facades, iron curtains such that they prevent Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 81 of 140 glass penetration for at least 90 seconds. 4 locks SIRA approved locks must be The above requirement is installed. excluded if the customer provides an automatic iron shutter that operates with a control button. 5 uninterruptible All cameras and recording - power supply devices must be connected to an uninterruptible power supply UPS for 30 minutes. 6 Access control An access control system must - system be installed on the main doors leading to the cashiers’ areas. Isolating the The cashier area and its - 7 cashier area from associated rooms must be the general areas separated from the rest of the of the store shop. 8 Installing system Installing system health - health monitoring monitoring service approved by service SIRA Fifth: Security Requirements for ATMs ATMs are electronic devices used to withdraw, deposit, and manage money independently, without the need for direct interaction with a bank employee. These devices provide a variety of convenient banking services to users. Types of ATMs: - Conventional: Perform basic functions such as withdrawing money and inquiring about the balance. - Multi-function: Provide additional services such as deposits, money transfers, and bill payments. - Banking Applications: Support additional banking applications and services such as opening new accounts or applying for loans. A. Cameras must be installed to meet the following requirements: VSS requirements SN Areas Field Of View Remarks 1 Inside the ATM Identification View - 2 On ATMs of all kinds Recognition View So that the cash filling angle is visible. 3 Recording retention period Not less than 75 days for all - cameras Note: If the ATM is old and does not have built-in cameras, external cameras must be installed in the Identification View to ensure a clear image of the ATM user. Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 82 of 140 Sixth: Security requirements for mobile ATMs A. Standards and conditions that must be met: Technical standards and conditions that must be met by mobile ATMs SN Requirement Details Remarks 1 The vehicle must be - Front section for driver's assistant - - internally divided and rear section (cabinet) into two sections. 2 The sections where The sections where the guards are - the guards are located must be air-conditioned and located are air- equipped with suitable seats and seat conditioned and belts for each person in the vehicle. equipped with seats. 3 ATM room armoring Only the ATM room to be armored on - only all sides to withstand any potential attack, emergency, or fire, provided that the armoring level is not less than B2 level according to international standards or its equivalent. 4 Using only one door Only one door should be used for entry Front doors are for entry and exit. and exit (side door) using both the ID used in card reader and the PIN. emergencies only and must be connected to a tracking system. 5 Forward view of the The vehicle crew's forward vision must - vehicle crew be at least 200 degrees with the naked eye. 6 Wheels with internal All wheels must be equipped with an - rubber tires internal rubber tread to ensure they will continue to travel for at least 110 km in the event of a puncture or damage. 7 Evacuation opening The dimensions of the evacuation the locks must dimensions opening must not be less than (60 cm be secure and * 60 cm) cannot be opened by normal means or tampered with. 8 The doors are All doors must be connected to a - connected with a unified locking system, operating on an unified locking interchange system so that the safe system. door will not open if any other door in the rear section is open. 9 door hinges Door hinges must be internal and of - high durability. 10 ATM room lock The ability to unlock the ATM room - using an ID card Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 83 of 140 11 Engine starting The engine starter system must be - The engine system linked to the vehicle entry system and starts when the the electronic starter system. entire crew checks in using their ID cards. 12 geographic tracking The vehicle must be equipped with a - system geographic coordinate system for determining the vehicle's location, approved by SIRA. 13 Geographical - Use a system approved by SIRA. - tracking system - Connected to the vehicle's operating requirements system so that the vehicle can be stopped remotely. - Vehicle movements must be monitored by the security service provider during business hours. 14 Vehicle Entry The vehicle must have an anti-theft or - System break-in alarm system, with a panic Requirements button within easy reach of the driver and their assistant and connected to the security service provider's central monitoring center. - All system cables in the vehicle must be shielded. 15 The following - The cash feed door must be located - Specifications must at the rear. be provided at the - It must be mounted on the floor of ATM: the vehicle. - Only the user panel must be visible from the ATM, with the rest of the machine hidden. - A minimum of 21 cm must be left between the rear entrance and the ATM, with a secure door to close the area if the vehicle is moving. - Any other equipment or supplies required by SIRA. 16 Vehicle weight The vehicle's weight after plating must - not exceed the weights specified by the vehicle manufacturer. If the weight exceeds the permissible limit, all of the vehicle's mechanical components must be modified to accommodate the new weight. 17 Equipped with The vehicle must be equipped with - emergency emergency equipment to deal with equipment sudden and minor vehicle breakdowns, Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 84 of 140 such as (flashlight, gloves, safety equipment, and first aid). 18 Provide adequate Adequate lighting must be provided - lighting around the vehicle and the ATM. B. Cameras must be installed in accordance with the following requirements: VSS requirements SN Areas Field Of View Remarks 1 In front Covers the front area of the vehicle Camera specifications at an angle of no less than 110° must not be less than IP66 when 2 In the back Covers the rear of the vehicle at Camera specifications an angle of no less than 110° must not be less than IP66. 3 Inside the Inside the middle compartment to Camera specifications middle cabin cover the safe door and the entry must not be less than and exit doors IP66. 4 On the right To cover the sides of the vehicle at Camera specifications and left sides an angle of not less than 90° must not be less than of the vehicle IP66. 5 Above the Observation View Camera specifications ATM must not be less than IP66. 6 inside the ATM The ATM requirements in this Camera specifications manual apply. must not be less than IP66. 7 Recording Recording must be at least 1080P - quality (Full HD) at 25 frames per second. Seventh: Security Requirements for Selling and Trading Digital Currencies Selling and trading digital currencies refers to the process of buying and selling digital currencies and other cryptocurrencies online. A. Cameras must be installed to meet the following requirements: VSS requirements SN Areas Field Of View Remarks 1 Entrances of the Identification View - establishment 2 cashier and reception desks Recognition View - 3 The safe Recognition View - 4 Lobby area Monitoring View - Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 85 of 140 5 ATMs Recognition View So that the cash filling angle is visible. B. Alarm system must be provided according to the following requirements: Alarm and intruder detection system (if a safe is available on site) SN Requirement Details Remarks Protected Areas, offices and All areas must be covered administration areas directly with motion sensors, connected to the shop including but not limited to protected areas, offices, and 1 administrative areas directly - connected to the shop, so that no area can be penetrated to stop or disable the security system. All glass facades of the - 2 glass facades facility must be secured with glass break sensors. Main and secondary - 3 Entrances and exits entrances and emergency exits, if any, must be equipped with magnetic keys. The safe The safe must be equipped - 4 with a vibration sensor or motion detector. The cashier, seller, and - manager must be provided with a panic button for use in 5 Panic button case of an emergency. It must be located at a level that is easy to use and not visible. Alarm system Alarm system components - 6 must be approved by SIRA C. The following security requirements must be provided: Other requirements SN Requirement Description Remarks 1 uninterruptible power All cameras and recording devices - supply must be connected to an uninterruptible power supply UPS for 30 minutes. Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 86 of 140 2 Installing system health Installing system health monitoring - monitoring service service approved by SIRA Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 87 of 140 Chapter Thirteen: Security Requirements for Sports and Recreational Halls and Clubs: These are facilities (buildings) where sports and recreational activities are conducted. First: Covered Activities Refer to the Commercial Facilities and Activities Annex Second: Specifications and Security Requirements A. Cameras must be installed in accordance with the following requirements: VSS requirements SN Areas Field Of View Remarks 1 Entrances of the Identification View - establishment 2 Internal areas of the Detection View - establishment 3 Establishment corridors Detection View - 4 cashier and reception Recognition View - desks 5 Passenger drop-off and Monitoring View - pick-up area 6 parking lots pathways Detection View - 7 Around the Detection View If the facility has its establishment’s own building perimeter 8 Recreational Areas and Detection View - Sports Arenas 9 Inside the storage rooms Detection View - 10 Installing car entrance Vehicles Number-Plate - cameras Recognition view B. The following security requirements must be provided: Other requirements SN Requirement Description Remarks 1 Installing system health Installing system health monitoring - monitoring service service approved by SIRA Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 88 of 140 Chapter Fourteen: Security Requirements for Gas Stations: These are facilities that provide fuel for cars and other vehicles to drivers and consumers. First: Activities Covered Refer to the Commercial Facilities and Activities Annex Second: Specifications and Security Requirements A. Cameras must be installed to meet the following requirements: VSS Requirements SN Areas Field Of View Remarks 1 Store entrance Identification View - 2 Vehicle fueling lines Monitoring View - 3 Petrol station fueling Monitoring View - Locations 4 Internal area of the store Detection View - 5 Vehicles Number-Plate Automatic Number- At the station Recognition cameras shall be Plate Recognition entrances and exits installed system (ANPR) approved by SIRA 6 Parking lots Detection View - 7 External washrooms Detection View - entrances 8 Cash register table Recognition View - 9 Areas of services provided by For example: vehicle the station Detection View washing and maintenance areas B. The following security requirements must be provided: Other requirements SN Requirement Description Remarks 1 Installing system health Installing system health monitoring - monitoring service service approved by SIRA Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 89 of 140 Chapter Fifteen: Security Requirements for Large and diverse Stores: Large and diverse stores include large retail chains that offer a wide range of products and services under one roof. These stores are often part of large shopping malls or operate as large individual stores. First: Activities Covered Review the Business Facilities and Activities Annex Second: Specifications and Security Requirements A. Cameras must be installed to meet the following requirements: VSS requirements SN Areas Field Of View Remarks 1 Entrances of the Identification View - establishment 2 emergency exit doors Observation View - among floors 3 elevators lobbies and stairs Observation View - 4 Inside the elevators Observation View With an angle showing the floor number, a wide-angle lens shall be used to cover all parts of the elevator. 5 cashier and reception desks Recognition View - 6 display tables Observation View - 7 Main store area and shelf Detection View - aisles 8 Building perimeter Detection View Installing cameras on the external perimeter of the establishment if the establishment has its own building. Note: If the facility has its own or rented parking spaces, cameras must be installed as follows: - Install an Automatic Number-Plate Recognition system (ANPR) approved by SIRA at the entrances and exits of the parking spaces. Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 90 of 140 - Install cameras along the parking lanes in Detection View. B. The following security requirements must be provided: Other requirements SN Requirement Description Remarks 1 Installing system health Installing system health monitoring - monitoring service service approved by SIRA Third: Specifications and Security Requirements for Department Store Buildings These are buildings that contain a main department store and additional stores that are leased and managed by the store management. A. Cameras must be installed to meet the following requirements: VSS requirements SN Areas Field Of View Remarks 1 Entrances of the Identification View - establishment 2 emergency exit doors Observation View - among floors 3 cashier and reception Recognition View - desks 4 elevators lobbies and Observation View - stairs 5 Inside the elevators Observation View With an angle showing the floor number, a wide- angle lens shall be used to cover all parts of the elevator. 6 ATM locations, public Recognition View So that the cash filling phones, and public angle is visible phone charging devices 7 Vehicle entrances and Recognition View - exits to the establishment 8 Safe and baggage Recognition View - storage rooms, temporary storage service for purchases 9 Vehicles Number-Plate Automatic Number-Plate - Recognition cameras Recognition system shall be installed Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 91 of 140 (ANPR) approved by SIRA 10 loading and unloading Monitoring View - areas 11 Passenger drop-off and Monitoring View - pick-up area 12 Establishment corridors Detection View - 13 Seating and waiting Detection View - areas 14 parking lots pathways Detection View - 15 Main lobby area Detection View - 16 Outdoor arenas, Monitoring View In addition to installing performance venues, PTZ cameras. and crowd gatherings 17 LPG storage area, filling Detection View - sites and gas cylinder storage areas. 18 Electrical room entrance Recognition View - 19 Water tank room Recognition View - entrance 20 Entrances to the fresh air Recognition View - handling units of the air conditioning system (FAHU) 21 Backup generator fuel Monitoring View - tanks B. The following security requirements must be provided: Other requirements SN Requirement Description Remarks 1 Operations room A dedicated operations room must be - provided to control and manage the cameras. It should be equipped with all means of communication with guards, department store officials, emergency, rescue, and ambulance services, and all other means of assistance to manage or control the security system. 2 Security Guard Providing 24-hour security guards - Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 92 of 140 3 Security operations Providing a security operations - manager or security supervisor around the clock 4 Security manager A security manager must always be - available on call. 5 female guard Female security personnel must be - present. 6 Security systems Providing a licensed security systems - operator operator, approved by SIRA, available 24/7 in the control room. 7 Hostile Vehicle Stationary or mobile HVM that are - Mitigation (HVM) approved shall be installed in front of the main gates and the areas where guests and visitors gather 8 Permanent Security Permanent Security Guards shall be - Guards for gathering provided for areas or corridors where areas of gold and shops of gold, jewelry and precious precious goods goods are located. shops 9 Installing system Installing system health monitoring - health monitoring service approved by SIRA service Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 93 of 140 Chapter Sixteen: Security Requirements for Electronic Games and Entertainment Halls and Arenas: Entertainment facilities that offer a variety of electronic games and recreational activities for visitors. First: Covered Activities Refer to the Commercial Facilities and Activities Annex Second: Specifications and Security Requirements A. Cameras must be installed to meet the following requirements: VSS requirements SN Areas Field Of View Remarks 1 Entrances of the Identification View - establishment 2 emergency exit doors Observation View - among floors 3 Establishment corridors Detection View - 4 elevators lobbies and Observation View - stairs 5 Inside the elevators Observation View With an angle showing the floor number, a wide-angle lens shall be used to cover all parts of the elevator. 6 Playrooms and areas Detection View - 7 cashier and reception Recognition View - desks 8 Inside the party rooms Detection View - 9 Vehicles Number-Plate Automatic Number-Plate For private or rented Recognition cameras Recognition system (ANPR) parking spaces shall be installed approved by SIRA 10 establishment Detection View Installing cameras on perimeter the external perimeter of the establishment if the establishment has its own dedicated premises / independent. Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 94 of 140 B. The following security requirements must be provided: Other requirements SN Requirement Description Remarks 1 Installing system health Installing system health monitoring - monitoring service service approved by SIRA Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 95 of 140 Chapter Seventeen: Security Requirements for Football Clubs: These are facilities that train athletes and organize football competitions. First: Activities Covered Refer to the Commercial Facilities and Activities Annex. Second: Specifications and Security Requirements A. Cameras must be installed in accordance with the following requirements: VSS requirements SN Areas Field Of View Remarks 1 Entrances of the establishment Identification View - 2 emergency exit doors among Observation View - floors 3 cashier and reception desks Recognition View - 4 Main lobby Detection View - 5 Seating and waiting areas Detection View - 6 Inside ticket outlets Recognition View - 7 elevators lobbies and stairs Observation View - 8 With an angle showing the floor Inside the elevators Observation View number, a wide- angle lens shall be used to cover all parts of the elevator. 9 ATM and public phones Locations Recognition View So that the cash filling angle is visible. 10 Loading and unloading areas Monitoring View - 11 Visitor drop-off and pick-up area Monitoring View - 12 Establishment corridors Detection View - 13 Fan stands and special platforms Detection View - 14 Parking pathways Detection View - 15 Outdoor areas, performance Monitoring View - venues, and visitor gatherings 16 LPG storage area and filling sites Observation View - and gas cylinder storage area 17 Electrical room entrance Recognition View - 18 Water tank room Recognition View - 19 Entrances to the fresh air handling Recognition View - units of the air conditioning system 20 Backup generator fuel tanks Detection View - Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 96 of 140 21 Vehicles Number-Plate Recognition Automatic Number- - cameras shall be installed Plate Recognition system (ANPR) approved by SIRA 22 The external perimeter of the Detection View - establishment B. The following security requirements must be provided: Other requirements SN Requirement Description Remarks 1 Security Guard Providing 24-hour security guards If the work system is 24 hours, this requirement must be met. Otherwise, security is provided during official working hours. 2 Operations Manager or Providing a security operations - Security Supervisor manager or security supervisor 3 female guard Female security personnel must be - available during official working hours. 4 operations room A dedicated operations room must - be provided to control and manage the cameras. It should be equipped with all means of communication with guards, club officials, emergency, rescue, and ambulance services, and all means of assistance to manage or control the security system. 5 Security Systems Providing a security systems - Operator operator in the control room on a continuous basis during working hours, and holding a license approved by the institution. 6 Installing system health Installing system health monitoring - monitoring service service approved by SIRA Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 97 of 140 Chapter Eighteen: Security Requirements for Warehouse compounds: First: Covered Activities Refer to the Commercial Facilities and Activities Annex Second: Security Requirements for Warehouse compounds Note: The responsibility for installing cameras in the warehouse compound lies with the compound owner. A. Cameras must be installed in accordance with the following requirements: VSS requirements SN Areas Field Of View Remarks 1 Installing cameras at car Vehicles Number- - entrances Plate Recognition view 2 External walkways between Detection View - warehouses 3 External perimeter Detection View - Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 98 of 140 Chapter Nineteen: Security Requirements for Warehouses: First: Covered Activities Refer to the Annex on Commercial Facilities and Activities Second: Security Requirements for General Warehouses: These are facilities used to store materials and equipment. A. Cameras must be installed to meet the following requirements: VSS requirements SN Areas Field Of View Remarks 1 Entrances of the establishment Identification View - 2 reception desks Recognition View - 3 Vehicles Number-Plate Recognition Vehicles Number- Vehicle entrances cameras shall be installed Plate Recognition and exits View 4 Loading and unloading areas Monitoring View - 5 Establishment corridors Detection View - 6 The internal area of the Detection View - warehouse 7 The outer area of the warehouse Detection View - B. The following security requirements must be provided: Other requirements SN Requirement Description Remarks 1 Installing system health Installing system health monitoring - monitoring service service approved by SIRA Third: Security requirements for hazardous and valuable materials warehouses: A. Cameras must be installed to meet the following requirements: VSS requirements SN Areas Field Of View Remarks 1 Entrances of the establishment Identification View - 2 reception desks Recognition View - 3 Vehicle entrances and exits to Vehicles Number-Plate - the establishment Recognition View 4 Loading and unloading areas Monitoring View - 5 The internal area of the Detection View - warehouse Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 99 of 140 6 The outer area of the Detection View The cameras are warehouse mounted on the outside wall of the warehouse. 7 Hazardous Materials Storage Recognition View For hazardous Container Door materials warehouses only B. An alarm system must be provided according to the following requirements (if the warehouse operates 24 hours, then it is exempted from this requirement) Alarm and intruder detection system SN Requirement Details Remarks Areas and rooms All areas and rooms with windows in - 1 the facility must be secured with motion detection sensors. Main and secondary entrances and - 2 Entrances and exits emergency exits, if any, must be equipped with magnetic keys. Alarm system Alarm system components must be - 3 certified by SIRA. C. The following security requirements must be provided: Other requirements SN Requirement Description Remarks 1 locks SIRA approved locks must be - installed. 2 Installing system health Installing system health monitoring - monitoring service service approved by SIRA Fourth: Security requirements for processed tobacco and tobacco cigarettes warehouses A. Cameras must be installed to meet the following requirements: VSS requirements SN Areas Field Of View Remarks 1 Entrances of the establishment Identification View - 2 reception desks Recognition View - 3 Vehicle entrances and exits to Vehicles Number-Plate - the establishment Recognition view 4 Loading and unloading areas Monitoring View - Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 100 of 140 5 Internal areas of the Detection View - warehouse 6 External areas of the The cameras are warehouse mounted on the Detection View outside wall of the warehouse. 7 Hazardous Materials Storage Recognition View For hazardous Container Door materials warehouses only B. An alarm system must be provided according to the following requirements (if the warehouse operates 24 hours, then it is exempted from this requirement): Alarm and intruder detection system SN Requirement Details Remarks Areas and rooms All areas and rooms with windows in - 1 the facility must be secured with motion detection sensors. Main and secondary entrances and - 2 Entrances and exits emergency exits, if any, must be equipped with magnetic keys. Alarm system Alarm system components must be - 3 approved by SIRA. C. The following security requirements must be provided: Other requirements SN Requirement Description Remarks 1 locks SIRA approved locks must be - installed. 2 Installing system health Installing system health monitoring - monitoring service service approved by SIRA Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 101 of 140 Chapter Twenty: Security Requirements for Self-storage: The process of storing goods or materials by individuals or companies, either manually or automatically. First: Covered Activities Refer to the Appendix on Establishments and Commercial Activities Second: Specifications and Security Requirements for Self-Storage A. Definitions: Definitions SN The term Definition 1 Safes area It is the area that contains iron safes and is surrounded by a cement wall. 2 stores area It is the area that contains a group of stores 3 Reception and waiting It is the area where customers are received and area dealt with, or the waiting room where they are served. 4 Viewing area It is the area where the customer can view his things privately and is within the protected area. 5 securing area It is the area that separates the safes area from the rest of the areas and is the only way for it. B. General Specifications: General Specifications of Facilities SN Requirement Details Remarks 1 Safe rental facilities for • Reception and waiting area. - storing valuable deposits • Safes area. must have the following • viewing area. divisions: • Securing area. • Administration area. 2 Self-storage facilities • Reception and waiting area. - must have the following • stores area. divisions: • Administration area 3 The securing area must The securing area must have at - have at least two doors. least two doors that open alternately, with one door being able to be opened only after the other is closed. Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 102 of 140 4 electric door locks Doors must have electric locks - that operate to open the doors when they are powered. 5 There must be backup • Alarm system (8 hours). - power to operate the • VSS system (8 hours). systems in the event of a • Doors system (8 hours). power outage as follows: C. Cameras must be installed in accordance with the following requirements: VSS requirements SN Areas Field Of View Remarks 1 Entrances of the Identification View - establishment 2 reception desks Recognition View - 3 Main lobby area Detection View - 4 sitting and waiting area Detection View - 5 Securing area Observation View - 6 Safe areas include all Monitoring View - spaces. 7 Viewing area Detection View - 8 Recording retention period Not less than 90 days for all - cameras D. Alarm system must be provided according to the following requirements: Alarm and intruder detection system SN Requirement Details Remarks 1 Motion and vibration Safes rooms must contain motion - detectors and vibration detectors. 2 Securing the main door The main door must have - magnetic keys. 3 Securing Areas and Rooms The reception area, security area, - and safes room must have a motion detector. 4 Panic button A panic button must be available at - the reception desk, the manager's office, and the security guard. 5 Alarm system All Alarm System components must - be certified by SIRA. Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 103 of 140 E. The following requirements must be provided: Other requirements SN Requirement Description Remarks 1 Security Guard Providing 24-hour security guards - 2 Taking tenant data The safe tenant's data must be taken with - a photo of his/her ID (such as an ID or passport). 3 Verify user identity There must be a system to verify the - identity of the user of The Safe. 4 Tenant Contracts All tenants must be bound by contracts - that include the following: 1. Not storing any harmful or prohibited materials. 2. Not storing any flammable or explosive materials. 3. Not storing materials stolen or obtained through a crime. 5 Installing system Installing system health monitoring service - health monitoring approved by SIRA service Third: Specifications and security requirements for automatic storage activities A. Definitions of automated storage activities: Definitions SN The term Definition 1 Safes area It is the area that contains iron safes and is surrounded by a cement wall. 2 Reception and waiting It is the area where customers are received and area dealt with, or the waiting room where they are served. 3 Viewing area It is the area where the customer can view his things privately and is within the protected area. Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 104 of 140 B. General Specifications of the automatic storage activity: General Specifications of Facilities SN Requirement Details Remarks 1 Automated self-storage • Reception and waiting area. - facilities must have the • Stores area. following divisions: • Administration area 2 electric door locks Doors must have electric locks - that operate to open the doors only when they are powered. 3 There must be backup • Alarm system (8 hours). - power to operate the • VSS system (8 hours). systems in the event of a • Doors system (8 hours). power outage. C. Cameras must be installed in accordance with the following requirements: VSS requirements SN Areas Field Of View Remarks 1 Entrances of the Identification View - establishment 2 reception desks Recognition View - 3 Main lobby area Detection View - 4 sitting and waiting area Detection View - 5 Safes maintenance Identification View - entrance and any access leading to the safes 6 Viewing area Detection View - 7 Recording retention period Not less than 90 days for all - cameras D. Alarm system must be provided according to the following requirements: Alarm and intruder detection system SN Requirement Details Remarks 1 main door The main door must have a door - contact. 2 Maintenance door The maintenance door to the safes - area and any entrance leading to the safes area must have door contact. 3 Reception and The reception and securing area - Securing Area must have a motion detector. Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 105 of 140 4 Panic Button A panic button must be available at - the reception desk and the security guard. 5 Alarm system All Alarm System components must - be certified by SIRA. E. The following requirements must be provided: Other requirements SN Requirement Description Remarks 1 security guard Providing 24-hour security guards - 2 The safe tenant The safe tenant's data must be taken with - details a photo of his/her identity proof (such as an ID or passport). 3 Identity Verification There must be a system to verify the - System identity of the user of The Safe. 4 Tenant Contracts All tenants must be bound by contracts - that comply with the following: 1. Not storing any harmful or prohibited materials. 2. Not storing any flammable or explosive materials. 3. Not storing materials stolen or obtained through a crime. 5 Installing system Installing system health monitoring service - health monitoring approved by SIRA service Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 106 of 140 Chapter Twenty-One: Security Requirements for Air Cargo: First: Covered Activities Refer to the Annex on Commercial Facilities and Activities Second: Security Requirements A. Cameras must be installed to meet the following requirements: VSS requirements SN Requirement Details Remarks 1 Entrances of the establishment Identification View - 2 reception desks Observation View - 3 Temporary and recovered material Recognition View - storage sites 4 Cargo inspection sites Recognition View - 5 Aisles and shelves in the facility Monitoring View - 6 Hazardous Material Storage Areas Recognition View - 7 Interior areas of the facility Detection View - 8 Inside the cargo handling rooms Detection View - 9 Loading and unloading areas Monitoring View - 10 Automatic Vehicles Number-Plate Automatic Number- - Recognition cameras shall be Plate Recognition installed system (ANPR) approved by SIRA 11 External facility perimeter Detection View - B. The following requirements must be provided: Other security requirements SN Requirement Description Remarks 1 security guard Providing 24-hour security guards - according to the risk analysis report 2 Security Providing a security operations If the work system Operations manager or security supervisor is 24/7, they must Manager or around the clock be provided. Security Supervisor 3 Access control Providing access control systems in On all gates leading system all areas of the facility. to the warehouse, 1. Electronic identification cards. emergency 2. Biometrics reader. entrances from the outside, and offices that require an access control system. Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 107 of 140 4 Installing system Installing system health monitoring - health monitoring service approved by SIRA service C. An Alarm system must be provided according to the following requirements if the operates less than (24) hours: Alarm system SN Requirement Details Remarks 1 motion detector All areas and rooms with windows in - the facility must be secured with motion detection sensors. 2 magnetic keys Main and secondary entrances and - emergency exits, if any, must be equipped with magnetic keys. 3 Panic button A panic button must be provided for - use in case of an emergency, at a level that is easy to use and not visible. Storage conditions and storage methods for hazardous materials, if applicable (smoke lights and construction bullets): - The container must be separated and in a suitable location. - The container must be enclosed or under a shelter. - Adequate ventilation must be provided for air inlet and outlet, or an air conditioning system must be provided. - The container's interior must be covered with insulating material or fire-resistant paint. - Provide cameras at the container gate. Provide fire extinguishers. - Provide a responsible person to coordinate and communicate with SIRA regarding incoming and outgoing shipments of hazardous materials. Maintain or leave sufficient space between containers. - Provide a fire alarm system with an annual maintenance contract. Note: 1. Regarding the storage or escorting of ammunition, explosives, and Class A hazardous materials, in coordination with the relevant authorities in the emirate. 2. segregation of ammunition and weapons must be ensured, ensuring they are stored in a single container. 3. Coordination must be made with the relevant authorities in the emirate to supervise the site and its operations. 4. Provide explosive and hazardous material detection devices approved by SIRA. Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 108 of 140 Chapter Twenty-Two: Security Requirements for Factories: These are facilities used to produce goods and products on a large scale through industrial processes. First: Activities Covered Refer to the Annex on Business Facilities and Activities Second: Specifications and Security Requirements for General Factories: A. Cameras must be installed to meet the following requirements: VSS requirements SN Areas Field Of View Remarks 1 Entrances of the establishment Identification View - 2 reception desks Recognition View - 3 Vehicle entrances and exits Vehicles number-plate - recognition view 4 Loading and unloading areas Monitoring View - 5 The interior of the factory Detection View - 6 Establishment corridors Detection View - 7 The external perimeter of the Detection View Installing factory cameras around the facility 8 Storage areas Detection View - 9 Hazardous Material Storage Recognition View - Container Doors B. The following security requirements must be provided: Other requirements SN Requirement Description Remarks 1 Installing system health Installing system health monitoring - monitoring service service approved by SIRA Third: Specifications and security requirements for hazardous materials factories: A. Cameras must be installed in accordance with the following requirements: VSS requirements SN Areas Field Of View Remarks 1 Entrances of the establishment Identification View - Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 109 of 140 2 reception desks Recognition View - 3 Vehicle entrances and exits to Vehicles number-plate - the establishment recognition view 4 Loading and unloading areas Monitoring View - 5 The interior of the factory Detection View - 6 Establishment corridors Detection View - 7 The external perimeter of the Detection View Installing establishment cameras around the facility 8 Storage areas Detection View - 9 storage container doors Recognition View - B. Alarm system must be provided according to the following requirements: Alarm and intruder detection system SN Requirement Details Remarks 1 Areas and rooms All areas and rooms with windows in the - facility must be secured with motion detection sensors. 2 Entrances and Main and secondary entrances and - exits emergency exits, if there are any, must be equipped with magnetic keys. 3 Panic button A panic button must be provided for use in - the event of an emergency, located at an easy-to-use, yet inconspicuous level. 4 Alarm system Alarm system components must be certified - by SIRA. Note: Requirements “B” above are excluded, in case the facility works 24/7. C. The following security requirements must be provided: Other requirements SN Requirement Description Remarks 1 Installing system health Installing system health monitoring - monitoring service service approved by SIRA Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 110 of 140 Fourth: Specifications and security requirements for tobacco processing and tobacco rolling factories (cigarettes): A. Cameras must be installed to meet the following requirements: VSS requirements SN Areas Field Of View Remarks 1 Entrances of the Identification View - establishment 2 reception desks Recognition View - 3 Vehicle entrances and Vehicles number-plate - exits recognition view 4 Loading and unloading Monitoring View - areas 5 The interior of the Detection View - factory 6 Establishment corridors Detection View - 7 The external perimeter Detection View Installing cameras around of the establishment the facility 8 Storage areas Detection View - 9 Hazardous Materials Recognition View - Storage Container Doors 10 spare parts room Detection View - 11 Quality Control Room Detection View - B. The following security requirements must be provided: Other requirements SN Requirement Description Remarks 1 security guard Providing 24-hour security guards - 2 Installing Installing system health monitoring service - system health approved by SIRA monitoring service Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 111 of 140 Chapter Twenty-Three: Security Requirements for Vacation Homes: Individually owned establishments rented on a daily, weekly, or monthly basis First: Covered Activities Refer to the Commercial Establishments and Activities Annex Second: Security Requirements A. The following security requirements must be provided for vacation homes: Requirements for Vacation homes SN Requirement Description Remarks 1 secure lock Installation of SIRA-approved secure - locks. 2 Lock App Use the SIRA approved smart lock - App 3 Secure Safe Installation of a safe approved by The safe must be SIRA. installed in a secure way that is difficult to remove. Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 112 of 140 Chapter Twenty-Four: Security Requirements for Shooting Ranges: These are facilities designated for practicing shooting sports, whether with firearms or bows and arrows. First: Covered Activities Refer to the Commercial Facilities and Activities Annex Second: Specifications and Security Requirements A. Cameras must be installed to meet the following requirements: VSS requirements SN Areas Field Of View Remarks 1 Entrances of the establishment Identification View - 2 cashier and reception desks Recognition View - 3 Weapons and ammunition Recognition View - delivery tables 4 Inside the weapons and Detection View - ammunition warehouse 5 Shooting lanes Recognition View - 6 Establishment corridors Detection View - 7 Vehicles Number-Plate Automatic - Recognition cameras shall be Number-Plate installed Recognition system (ANPR) approved by SIRA 8 parking lots pathways Detection View - B. The following security requirements must be provided: Other requirements SN Requirement Description Remarks 1 Installing system health Installing system health monitoring - monitoring service service approved by SIRA Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 113 of 140 Chapter Twenty-Five: Security Requirements for Art Galleries: These are spaces designated for displaying artworks such as paintings, statues, photographs, and art installations. These galleries are used for displaying artworks. First: Covered Activities Refer to the Commercial Facilities and Activities Annex Second: Specifications and Security Requirements A. Cameras must be installed to meet the following requirements: VSS requirements SN Areas Field Of View Remarks 1 Entrances of the establishment Identification View - 2 cashier and reception desks Recognition View - 3 Display tables and display areas Observation View - 4 Vehicle entrances and exits to Vehicles number- If the establishment the establishment plate recognition has its own parking view spaces 5 Main lobby Detection View - B. An alarm system must be provided for facilities that contain a piece of no less than 100,000 dirhams or a total of no less than one million dirhams, according to the following requirements: Alarm and intruder detection system SN Requirement Details Remarks 1 Showroom Coverage Covering the showroom with - motion sensors so that no area can be penetrated to stop or disable the security system. 2 glass facades All glass facades of the facility - must be secured with glass break sensors or motion detection sensors. 3 Entrances and exits Main and secondary entrances - and emergency exits, if any, must be equipped with magnetic keys (Door contacts) or motion detectors. 4 The safe The safe must be equipped with - a vibration sensor or motion detector. Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 114 of 140 5 Panic button The cashier, seller, and manager - must be provided with a panic button for use in case of an emergency. It must be located at a level that is easy to use and not visible. 6 Alarm system Alarm system approved by SIRA - C. The following security requirements must be provided: Other requirements SN Requirement Description Remarks 1 Providing security Security must be provided during - guards official working hours. 2 Installing system health Installing system health monitoring - monitoring service service approved by SIRA Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 115 of 140 Chapter Twenty-Six: Security Requirements for Vehicle Rental Shops: These are premises that provide vehicle rental services to individuals or companies for specific periods. First: Covered Activities Refer to the Commercial Establishments and Activities Annex Second: Specifications and Security Requirements A. Cameras must be installed to meet the following requirements: VSS requirements SN Areas Field Of View Remarks 1 Entrances of the establishment Identification View - 2 cashier and reception desks Recognition View - 3 Contract editing tables Recognition View - 4 The internal area of the shop Detection View - B. The following security requirements must be provided: Other requirements SN Requirement Description Remarks 1 Installing system health Installing system health monitoring - monitoring service service approved by SIRA Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 116 of 140 Chapter Twenty-Seven: Security Requirements for Tobacco Retail Stores: Establishments that sell tobacco and cigarette products, as well as other related products such as e-cigarettes, pipes, luxury cigarettes, and related accessories. First: Activities Covered Refer to the Business Establishments and Activities Annex. Second: Specifications and Security Requirements A. Cameras must be installed to meet the following requirements: VSS requirements SN Areas Field Of View Remarks 1 Entrances of the Identification View - establishment 2 cash tables Recognition View - 3 Internal space of the Detection View - store 4 The store’s external Observation View - area 5 Store room Detection View - B. The following security requirements must be provided: Other requirements SN Requirement Description Remarks 1 Installing system health Installing system health monitoring - monitoring service service approved by SIRA Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 117 of 140 Chapter Twenty-Eight: Security Requirements for Precious Goods Stores: These stores specialize in buying and selling high-value goods, such as global brands, luxury watches, and rare currencies. These include commercial establishments that sell precious items valued at more than AED 10,000. First: Covered Activities Refer to the Commercial Establishments and Activities Appendix Second: Specifications and Security Requirements A. Cameras must be installed to meet the following requirements: VSS requirements SN Areas Field Of View Remarks 1 Entrances of the establishment Identification View - 2 cashier and reception desks Recognition View - 3 display tables Observation View - 4 Covering the internal space of the Detection View - store B. An alarm system must be provided for facilities that contain a piece of no less than 100,000 dirhams or a total of no less than one million dirhams, according to the following requirements: Alarm system SN Requirement Details Remarks 1 Protected areas, offices and Covering all areas with motion - administration areas directly sensors is comprehensive and connected to the store not limited to protected areas, offices, and administrative areas directly connected to the store, so that no area can be breached to stop or disable the security system. 2 glass facades All glass facades of the facility - must be secured with glass breakage sensors or motion detection sensors. 3 Entrances and exits Main and secondary entrances - and emergency exits, if any, must be equipped with magnetic keys (Door contacts) or motion detectors. 4 The safe The safe must be equipped - with a vibration sensor or motion detector. Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 118 of 140 5 Panic button The cashier, seller, and - manager must be provided with a panic button for use in case of an emergency. It must be located at a level that is easy to use and not visible. 6 Alarm system All components of the alarm - system must be approved by SIRA. C. The following security requirements must be provided: Other requirements SN Requirement Description Remarks 1 Installing system health Installing system health monitoring - monitoring service service approved by SIRA Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 119 of 140 Chapter Twenty-Nine: Security Requirements for Data Centers: Data centers are facilities used to host computing systems and store data securely and efficiently. First: Covered Activities Refer to the Facilities and Business Activities Annex Second: Specifications and Security Requirements A. Cameras must be installed to meet the following requirements: VSS requirements SN Areas Field Of View Remarks 1 Entrances of the establishment Identification View - 2 Establishment corridors Detection View - 3 elevators lobbies and stairs Observation View - 4 Inside the elevators Observation View - 5 cashier and reception desks Recognition View - 6 Main lobby Detection View - 7 Seating and waiting areas Detection View - 8 Inside server rooms Detection View - 9 Electrical and mechanical room Recognition View - entrances 10 Installing cameras at the car Vehicles Number-Plate - entrance Recognition view 11 The external perimeter of the Detection View Installing cameras establishment around the facility 12 the pre-stage area before Recognition View - entering the server room 13 Inside the Network Operations Detection View - Center 14 Backup Power Supply (UPS) Detection View - Room Entrances Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 120 of 140 B. The following security requirements must be provided: Other requirements SN Requirement Description Remarks 1 Access control system for server Electromechanical room locks must be used. Access control system 2 Only one door of the protected area - must be enabled to open, and the other door must not open until the Access control first door is closed. system 3 security guard Must provide 24-hour security guards - according to the risk analysis report 4 Installing system Installing system health monitoring - health monitoring service approved by SIRA service Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 121 of 140 Chapter Thirty: Security Requirements for Pharmacies: These are commercial establishments that provide medicines, medical supplies, and health products to customers. First: Activities Covered Refer to the Commercial Establishments and Activities Annex Second: Specifications and Security Requirements A. Cameras must be installed to meet the following requirements: VSS requirements SN Areas Field Of View Remarks 1 Entrances of the Identification View - establishment 2 cashier and reception desks Recognition View - 3 Inside the Establishment Detection View - areas 4 Entrance to medicine Recognition View - storage rooms 5 restricted medicine cabinet Recognition View - B. The following security requirements must be provided: Other requirements SN Requirement Description Remarks 1 Installing system health Installing system health monitoring - monitoring service service approved by SIRA Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 122 of 140 Chapter Thirty-One: Security Requirements for Massage Centers: A place that provides massage and physiotherapy services for the body for the purpose of relaxation, stress relief, and improving general health. First: Covered Activities Refer to the Commercial Establishments and Activities Annex Second: Specifications and Security Requirements A. Cameras must be installed to meet the following requirements: VSS requirements SN Areas Field Of View Remarks 1 Entrances of the Identification View - establishment 2 cashier and reception desks Recognition View - 3 Waiting areas Detection View - B. The following security requirements must be provided: Other requirements SN Requirement Description Remarks 1 Installing system health Installing system health monitoring - monitoring service service approved by SIRA Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 123 of 140 Chapter Thirty-Two: Security Requirements for Parking Rental and Management Services: These are services that help individuals and companies provide and manage parking spaces. First: Covered Activities Refer to the Commercial Facilities and Activities Annex Second: Specifications and Security Requirements A. Cameras must be installed to meet the following requirements: VSS requirements SN Areas Field Of View Remarks 1 Entrances of the Identification View - establishment 2 emergency exit doors Observation View - among floors 3 parking lots pathways Detection View - 4 Establishment corridors Detection View - 5 elevators lobbies and Observation View - stairs 6 Payment areas Observation View - 7 Vehicles Number-Plate Automatic Number-Plate Vehicle Recognition cameras shall Recognition system (ANPR) entrances and be installed. Or the approved by SIRA exits to the registration system establishment approved by SIRA B. The following security requirements must be provided: Other requirements SN Requirement Description Remarks 1 Installing system health Installing system health monitoring - monitoring service service approved by SIRA Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 124 of 140 Chapter Thirty-Three: Security Requirements for Auction Halls: Commercial establishments that sell goods or items by public auction. These halls are considered places for the public exchange and sale of goods based on bids submitted by the public. First: Activities Covered Refer to the Commercial Establishments and Activities Annex Second: Specifications and Security Requirements A. Cameras must be installed to meet the following requirements: VSS requirements SN Areas Field Of View Remarks 1 Entrances of the Identification View - establishment 2 Seating and waiting areas Detection View - 3 Establishment corridors Detection View - 4 Collectibles display area Detection View For large items such as cars and heavy vehicles 5 Auction halls Detection View - 6 The main safe room Recognition View - 7 Vehicles Number-Plate Vehicles Number-Plate For own or rented Recognition cameras Recognition view parking spaces 8 The external perimeter of Detection View In the case of external the establishment sales halls B. The following security requirements must be provided: Other requirements SN Requirement Description Remarks 1 Installing system health Installing system health monitoring - monitoring service service approved by SIRA Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 125 of 140 Chapter Thirty-Four: Security Requirements for Customer Happiness Centers: Customer Happiness Centers are facilities that aim to improve customer experience and increase customer satisfaction with the services or products offered by a company or organization. These centers are essential in providing support and assistance to customers and offer a wide range of services. First: Activities Covered Refer to the Business Establishments and Activities Annex Second: Specifications and Security Requirements A. Cameras must be installed to meet the following requirements: VSS requirements SN Areas Field Of View Remarks 1 Entrances of the Identification View - establishment 2 Establishment Detection View - corridors 3 elevators lobbies and Observation View - stairs 4 Inside the elevators Observation View With an angle showing the floor number, a wide-angle lens shall be used to cover all parts of the elevator. 5 Waiting halls Detection View - 6 cashier and reception Recognition View - desks 7 Public parking Automatic Number-Plate For the establishment own entrances and exits Recognition system parking or rented parking (ANPR) approved by SIRA spaces 8 The external Detection View perimeter of the establishment B. The following security requirements must be provided: Other requirements SN Requirement Description Remarks 1 Installing system health Installing system health monitoring - monitoring service service approved by SIRA Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 126 of 140 Chapter Thirty-Five: Security Requirements for Business Centers: These are designated spaces that provide a comfortable work environment and are equipped with the tools and facilities businessmen and owners of small and medium- sized enterprises (SMEs) need to run their businesses efficiently. These offices can be traditional or shared offices and offer a variety of services that facilitate business. First: Covered Activities Refer to the Business Establishments and Activities Annex Second: Specifications and Security Requirements A. Cameras must be installed to meet the following requirements: VSS requirements SN Requirement Details Remarks 1 Entrances of the Identification View - establishment 2 emergency exit doors among Observation View - floors 3 Establishment corridors Detection View - 4 elevators lobbies and stairs Observation View - 5 Waiting halls Detection View - 6 Customer service tables Recognition View - 7 cashier and reception desks Recognition View - B. The following security requirements must be provided: Other requirements SN Requirement Description Remarks 1 Installing system health Installing system health monitoring - monitoring service service approved by SIRA Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 127 of 140 Chapter Thirty-Six: Security Requirements and Conditions for Quran Memorization Centers and Islamic Institutions: Quran memorization centers and Islamic institutions include establishments dedicated to teaching and memorizing the Holy Quran, religious lessons, and Islamic culture in general. First: Activities Covered Refer to the annex for commercial establishments and activities Second: Specifications and Security Requirements A. Cameras must be installed in accordance with the following requirements: VSS requirements SN Areas Field Of View Remarks 1 Entrances of the establishment Identification View - 2 Installing external cameras Detection View - around the building's perimeter 3 Establishment corridors Detection View - 4 elevators lobbies and stairs Observation View - 5 With an angle showing the floor Inside the elevators Observation View number, a wide- angle lens shall be used to cover all parts of the elevator. 6 cashier and reception desks Recognition View - 7 Cash storage and sorting areas Recognition View - 8 The safe Recognition View - 9 Inside classrooms Detection View - 10 Inside the activity halls Detection View - 11 Inside the event halls Detection View - 12 sitting and waiting area Detection View - 13 Inside the library Detection View - 14 Inside the theater Detection View - 15 Inside the men's prayer hall and Detection View - the corridor leading to the women’s prayer hall. 16 Inside the filing rooms Detection View - 17 Storage rooms Detection View - 18 parking lots pathways Detection View - 19 Vehicles Number-Plate Automatic Number- If own parking is Recognition cameras shall be Plate Recognition available installed system (ANPR) approved by SIRA Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 128 of 140 20 Recording retention period Not less than 60 - days for all cameras B. Alarm system must be provided according to the following requirements: Alarm system SN Requirement Details Remarks The safe and places to store The cabinet / safe - 1 valuables must be equipped with a vibration sensor or motion detector. Cash storage, - sorting, the safe, and cash receiving tables must be equipped with a panic button for use in the event 2 Panic button of an emergency, located at an easy- to-use and invisible place. All Alarm System - 3 Alarm system components must be certified by SIRA. C. The following security requirements must be provided: Other requirements SN Requirement Description Remarks 1 Access control system - Rooms - - Offices - Cash storage and sorting areas 2 Installing system health Installing system - monitoring service health monitoring service approved by SIRA Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 129 of 140 Chapter Thirty-Seven: Security Requirements for Charitable Organizations: These are non-profit organizations that aim to provide support and assistance to individuals and communities in need. First: Covered Activities Refer to the Commercial Facilities and Activities Annex Second: Specifications and Security Requirements A. Cameras must be installed to meet the following requirements: VSS requirements SN Areas Field Of View Remarks 1 Entrances of the Identification View - establishment 2 The external perimeter of Detection View - the establishment 3 Establishment corridors Detection View - 4 elevators lobbies and Observation View - stairs 5 cashier and reception Recognition View - desks 6 Cash storage and sorting Recognition View - areas 7 The safe room Recognition View - 8 Storage rooms Detection View - 9 Vehicle entrances and Vehicles Number-Plate - exits Recognition view B. Alarm system must be provided according to the following requirements: Alarm and intruder detection system SN Requirement Details Remarks The safe and The cabinet must be equipped with a - 1 storage areas for vibration sensor or motion detector. valuable materials A panic button must be installed in - 2 Panic button the safe, cash storage and sorting areas, and cash receiving tables for use in the event of an emergency. It must be located at an easy-to-use and inconspicuous location. Alarm system All Alarm System components must - 3 be certified by SIRA. C. The following security requirements must be provided: Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 130 of 140 Other requirements SN Requirement Description Remarks 1 Access control Installation of an access control - system system for all rooms, including the safe and cash storage and sorting room. 2 Installing system Installing system health monitoring - health monitoring service approved by SIRA service Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 131 of 140 Chapter Thirty-Eight: Security Requirements for Hunting Equipment Stores: Hunting equipment stores are stores that offer a variety of Hunting-related equipment and supplies. First: Activities Covered Refer to the Business Establishments and Activities Annex Second: Specifications and Security Requirements A. Cameras must be installed to meet the following requirements: VSS requirements SN Areas Field Of View Remarks 1 Entrances of the Identification View - establishment 2 Cash and reception tables Recognition View - 3 display tables Observation View - 4 Storage areas Detection View - 5 Shop area Detection View - B. The following security requirements must be provided: Other requirements SN Requirement Description Remarks 1 Installing system health Installing system health monitoring - monitoring service service approved by SIRA Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 132 of 140 Chapter Thirty-Nine: Security Requirements and Conditions for the Security Monitoring Operations Center: The Security Monitoring Operations Center is a center responsible for monitoring operations for various facilities and sectors. First: Covered Activities Refer to the Establishments and Commercial Activities Annex Second: Specifications and Security Requirements A. Operations centers must have the following requirements and Specifications: 1. The operations room must be no less than 300 square feet in area, and its area may increase as deemed necessary by SIRA. 2. The operations room must operate 24 hours a day, 7 days a week, year-round. 3. The number of staff in the room must be no less than two, in addition to the room manager. This number may increase depending on the room's size and systems. 4. A means of communication must be provided between the operations room and security personnel according to their locations. 5. The operations room must be connected to the security authorities in the emirate. 6. A hotline must be provided with the relevant authorities in the emirate. 7. The operations room must be secured with a VSS system and an alarm system linked to the security authorities in the emirate. 8. Providing a backup energy source for computer systems that works with a battery for a period of not less than 8 hours. 9. The main power source of the room must be linked to a backup generator that operates automatically in emergency situations when the electricity is interrupted so that it operates all the equipment and devices in the room. 10. The time must be matching on all the devices in the room with the actual time. 11 Provide Safety systems. 12. a maintenance contract for all operating room devices. 13. an evacuation plan and an emergency plan known by the operating room staff. 14. Consider providing enough spaces for the following: • space for devices. • A space for the control room employees. • A space for large screens (if necessary.) • Sufficient space for maintenance. • Space for services. 15. must not contain windows that reveal the details of the work for those outside the room. 16. Its place should be protected from attacks or penetration. 17 It has additional wiring channels. 18. Protect wiring outlets from reptiles, rodents, and anything that could cause the connections to be cut or damaged. 19. Use furniture designed for extended periods. 20. Ensure that wires and connections are concealed. 21. Place recording devices, accessories, and wires in secure containers. 22. Install surveillance cameras to cover all activities within the control room at detection view. 23. The following activities are prohibited in the operating room: • Smoking. • Eating. Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 133 of 140 • Using the systems or room for purposes other than security purposes. • Filming with mobile phones. Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 134 of 140 Chapter Forty: Security Requirements for the Transport of Money and Valuable Materials: First: Covered Activities Refer to the Appendix on Commercial Establishments and Activities Second: Specifications and Security Requirements A. The technical standards and requirements that must be met by vehicles transporting money and valuable materials are as follows: Technical standards and conditions SN Requirement Details Remarks 1 - Front section for the driver - and co-driver The vehicle should be - Middle section for the divided internally into three assistant guard sections. - Rear section (locker) 2 The sections where the guards - The sections where the are located must be air- guards are located are air- conditioned and equipped with conditioned and equipped suitable seats and seat belts with seats. for each person in the vehicle. 3 Vehicle armoring Fully armored on all sides to - withstand any potential attack, emergency, or fire, provided that the armoring level is not less than B4, according to international standards or equivalent. 4 Use only one door for entry Only one door should be used Front doors are and exit. for entry and exit (side door) used only in using both the ID card reader emergencies and and the PIN. must be connected to the alarm system. 5 Forward view of the vehicle The vehicle crew's forward - crew vision must be at least 200 degrees with the naked eye. 6 The wheels are equipped All wheels must be equipped - with internal rubber tires. with an internal rubber tire to ensure they will continue to travel for at least 100 km in the event of a puncture or damage. Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 135 of 140 7 Evacuation opening The dimensions of the Its locks must be dimensions evacuation opening must not secure and be less than 60 cm * 60 cm. cannot be opened by normal means or tampered with. 8 The doors must be All doors must be connected to - connected with a unified a single electro-mechanical locking system. locking system with an interchange system (Interchange system: The safe door will not open if any other door of the rear section is open) 9 door hinges Door hinges must be internal - and of high durability. 10 Double-open safe lock The safe lock must be - equipped with a digital and biometric key. 11 Engine starting system The engine starter system - The engine must be linked to the vehicle starts when the entry system and theentire crew electronic starter system. checks in using their ID cards. - The speed limiter is activated when cash transfer personnel exit the vehicle. 12 geographic tracking system The vehicle must be equipped - with a geographic coordinate system for determining the vehicle's location, approved by SIRA, and capable of being linked to the central monitoring center of the security service provider. 13 Panic button The vehicle must have an anti- - theft or break-in alarm system, and the panic button must be accessible to the driver and his assistant and connected to the service provider's central monitoring center. 14 Equipped with safety The vehicle must be equipped - equipment with firefighting and first aid equipment. B. Cameras must be installed and comply with the following requirements: Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 136 of 140 VSS requirements SN Requirement Details Remarks 1 In front Covers the front area of the vehicle at an Camera angle of no less than 110° specifications must not be less than IP66 when installing external cameras. 2 In the back Covers the rear of the vehicle at an angle Camera of no less than 110° specifications must not be less than IP66. 3 Inside the Inside the middle compartment to cover - middle cabin the safe door and the entry and exit doors 4 On the right and To cover the sides of the vehicle at an Camera left sides of the angle of not less than 90° specifications vehicle must not be less than IP66. Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 137 of 140 Chapter Forty-One: Security Requirements for Vehicle safety and Protection: First: Covered Vehicles Refer to the Commercial Establishments and Activities Annex included vehicles Hazardous Materials Transport Vehicles Tourist vehicles and buses Rental vehicles Rental buses Luxury passenger transport vehicles Second: Specifications and Security Requirements A. Install a tracking system approved by SIRA. B. Install cameras on vehicles transporting hazardous materials according to the following requirements: - Inside the driver's cabin, ensuring the cabin is fully visible. - On the outside of the vehicle's hazardous materials loading area. - Install cameras directed at the road ahead and rear of the vehicle. - Recording quality must not be less than 30 frames per second. Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 138 of 140 Chapter Forty-Two: Security Requirements for Transfer and Delivery of Money: First: Covered Activities Refer to the Appendix on Commercial Establishments and Activities Second: Specifications and Security Requirements A. All money transfer companies and their clients must adhere to the following: Requirements for transferring and delivering money SN Requirement Details Remarks 1 Pick-up and Receiving and delivering cash in secure, - delivery sealed bags with serial numbers. 2 Pick-up and The customer's pickup and delivery must - delivery locations take place in a secure location monitored by cameras to record the process. 3 Package safety Both the sending and receiving parties - must ensure that the package is intact, tightly sealed, and has a serial number. 4 Money may not The money transfer company employee - be counted by a is prohibited from counting the money money transfer before receiving it. His role is limited to company transporting the bag of money only. employee. 5 Bag opening site The bag must only be opened at the - cash center by a designated employee under camera surveillance, after ensuring the integrity of the bag and the bag lock's security serial number. 6 The party In the event of any breach or damage to - responsible in the bag, the money transfer company is case of a breach responsible for any money missing from or damage the total amount in the bag received by the customer. 7 Procedure for If the bag is intact and the amount - detecting a differs from what the customer stated, discrepancy in the money transfer company must amounts inform the customer immediately or provide him with a video showing the bag opening process, along with the bag's safety and serial number. Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 139 of 140 Chapter Forty-Three: Communication and Communicating Requirements for Security guard Service Providers: First: Covered Activities Refer to the Appendix for Establishments and Commercial Activities Second: Security Requirements A. All security guard service providers operating in the activities covered in Paragraph (First) must use the communication and security devices for security work that is approved by SIRA and the security apps for smart devices that is approved by SIRA as follows: 1. For communication between company management and security personnel. 2. For communication between security personnel. 3. When security personnel communicate with security and safety authorities in the emirate. B. The watchman must use the communication and security devices for security work that is approved by SIRA and the security apps for smart devices that is approved by SIRA Administrative Resolution No. (13) of 2025 Approving the Preventive Systems Manual Page 140 of 140

dubai administrative resolution no 13 of 2025 preventive system manual (from the file; to confirm against the document) · Nelum